2019-11-18 | Technical improvements, changes in design, printing- and other errors expected.
11
3.2.4.
Static (Independent Output) und (Shared Output)
It is possible to configure up to 32 user bands in static mode.
If you click the blue arrow button on the unicable output, you can set the number of active user bands for this
port.
The following settings are then available in the table for each user tape:
Frequency
Enter the frequency of the user band (the frequencies must not overlap).
Transponder
Select the frequency of the transponder to be converted to the user band.
Polarization
Select the polarization of the transponder
Bandwidth
Select the bandwidth of the user band (this should be the same or larger than the transponder bandwidth).
Channelizer AGC Offset
You can activate "Advanced Mode" in the "View" menu. This allows the output power per user band to be set
(see also chapter 6 "Level table for converting dBm to dBµV" on page 16).