background image

Field of application

The devices are suited only for amplifying radio, television and DOCSIS signals 
in the house! If the device is used for other purposes, no warranty is given!

Equipotential bonding and Mounting

 

To avoid dangerous overvoltages (attention: risk of fire/death), the devices 
must be connected to the equipotential bonding according to EN 60728-11.

 

Use the equipotential bonding connection attached to the device (1).

 

To connect the outer conductor of the coaxial cable to the equipotential 
bonding, use e.g. earth connection blocks CFA or earthing angles QEW at 
the input and output of the amplifier. 

 

Use the mounting screws included in the delivery and the mounting holes 
of the devices (2).

2

2

1

Input

Output

Test ports

Remote power feeding

The BVS 20-66 is supplied over the coaxial cable. The jumper (PS) is used to 
decide between remote power supply at the input (position „Eingang“) or 
at the output (position „Ausgang“). 

 

Install according to this a power inserter TZU 15-01 at the input or at the 
output of the amplifier. 

 

Connect a remote feed transformer BZU 100-00 via a remote feed cable 
BZU 150-00 to the power inserter.

RF Installation

 

Connect the input of the amplifier to the interconnection point. Connect the 
output of the amplifier to your house distribution.

 

Use a highly shielded coaxial cable with an F connector. Suitable cables and 
connectors can be found in the current AXING catalogue or under www.
axing.com.

Downstream adjustments

 

Use the jumpers (DS J1 and DS J2) to adjust the interstage attenuation and 
slope. 

 

If this is not sufficient, adjust the the input attenuation and slope using the 
attenuators (DS 1 and DS 2) in the forward frequency range. 

Upstream adjustments

 

Use the jumpers (US J1 and US J2) to adjust the interstage attenuation and 
slope. 

 

If this is not sufficient, adjust the input attenuation of the return path with 
the attenuator (US). 

Activate and deactivate the test port at the input

The test port at the input is bi-directional. This test port must therefore be 
activated for measurement by means of a jumper:

 

Jumper in position ON = test port active

After measuring or adjusting the level of the amplifier, the measuring socket 
must be deactivated again:

 

Jumper in position OFF = test port deactivated

Power indicator LED

The amplifier comes with a LED (POWER) which shows the operation mode:

 

green = in operation 

 

out = no power supply

BSD 963-11N

BSD 963-12N

BSD 963-17N

QEW 5-50

BVE 4-02P

TV

CMO 2-01

BVS 20-66

Koax
Coax
Up- und Downstream (Koax)
Up- and Downstream (Coax)
Potentialausgleich
Equipotential bonding

HÜP

IP

Page 2 of 2 | AXING-BA_BVS-20-66 | 2022-11-24

Отзывы: