BVS 20-66
premium
-line
CATV amplifiers
Operation instructions
Technical data
Type
BVS 20-66
EMC
according to EN 50083-2, class A
Downstream
Frequency range
85…1006 MHz
Gain
38 dB
Max. output level CSO/CTB (CENELEC ras-
ter, 41 channels, 60 dB IMA)
107 dBµV
Attenuation: adjustable in 1 dB steps
0…15 dB
Equalization: adjustable in 1 dB steps
0…15 dB
Attenuation interstage: pluggable with
jumpers
0 | 2 | 4 | 6 dB
Equalization interstage: pluggable with
jumpers
0 | 2 | 4 | 6 dB
Return loss
≥ 18 dB (-1.5 dB/Octave)
Noise figure typ.
≤ 5.5 dB
Upstream
Frequency range
5…65 MHz
Gain
30 dB
Noise figure
≤ 7 dB
Attenuation: continuously adjustable
0…15 dB
Equalization interstage: pluggable with
jumpers
0 | 3 | 6 | 9 dB
Attenuation interstage: pluggable with
jumpers
0 | 6 dB
RF connectors
Type
F-female
Test port at in-/output
-20 ±2.5 dB/-20 ±1.0 dB
General
Switching power supply
30...65 VAC / 50...60 Hz
Power indicator
LED
Power consumption
10 W
Equipotential bonding connection
4 mm²
Operating temperature range
(acc. to EN 60065)
-20…+50°C
Dimensions (W × H × D) appr.
195 × 90 × 55 mm
Weight
0.480 kg
IP code
IP54
Observe the safety instructions supplied with the device!
They are also available at the following Internet address:
https://download.axing.com/BAs/Sicherheitshinweise_9sprachig.pdf
Use the device only as described in these operating instructions and in
particular in accordance with the state of the art.
If the device is used for other purposes, no warranty will be assumed!
Page 1 of 2 | AXING-BA_BVS-20-66 | 2022-11-24
Technical improvements, changes in design, printing and other errors reserved.
Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EEA contact address
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
EU Declaration of Conformity
Hereby AXING AG declares that the CE marked products comply with the
valid EU guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.