axing OTX 1310-10 Скачать руководство пользователя страница 3

2017-10-03 | Technical improvements, changes in design, printing- and other errors expected.

11

Safety instructions

The core part of OTX 1310-10 is a ESD laser.

Please obey the operation rule strictly and carefully when disassemble and assemble. The wrist belt and
the union suit should be also grounded.

All electric power and optical transmitter should be given a good grounding connection.

The electric power of the optical transmitter should be 90…265VAC and a regulated AC power is
suggested.

The RF signal must not be connected until the optical transmitter arrives at it’s normal working point. The
amplitude of the RF signal should follow the instructions in the test report of the optical transmitter. An
abnormal RF signal power will overload and damage the laser.

The optical transmitter should be stored in a ESD protection environment (such as a ESD protection
container) and cannot be stored with corrosive cargo. The store temperature should be within -20

℃ ~

+50

.

Forced cooling should be added when multiple optical transmitters are mounted on the same rack.

Please don’t open or repair any part of the transmitter, otherwise the producer don’t pay the fiddler.

Eyes may be hurt if you watch the optical output directly.

The heat elimination hole should not be blocked. The transmitter need good airing to work properly.

The optical output should be covered with our dust-proof if the transmitter don’t work for a long period.

When failure occurs

,

the transmitter should be sent to the producer in time. And please don’t open or

repair any part of the transmitter, otherwise the producer don’t pay the fiddler

Direct eye exposure to laser beam may cause physical damage

Содержание OTX 1310-10

Страница 1: ...OTX 1310 10 Optical Transmitter Operation Instructions...

Страница 2: ...ront and rear panel 5 2 1 Operating elements on the front panel 5 2 2 Connectors on the rear panel 6 3 Installation 7 3 1 Menu Interface 8 4 WEB Management 10 4 1 Parameters 10 4 2 Settings 11 4 3 Inf...

Страница 3: ...ill overload and damage the laser The optical transmitter should be stored in a ESD protection environment such as a ESD protection container and cannot be stored with corrosive cargo The store temper...

Страница 4: ...tter has following functions AGC MGC mode Low noise DFB laser Adjustable OMI SNMP Simple Network Management Protocol for administration and monitoring Furthermore it has two redundant plug in power su...

Страница 5: ...ser Temperature T COOL CURRENT mA Power supply 24 4V 5 4V 5 4V s Voltage detecting IP address Gateway OMI Inner temperature 2 LEDs green means that it works fine red meansfailed RF is for input levels...

Страница 6: ...Technical improvements changes in design printing and other errors expected 2 2 Connectors on the rear panel 6 6 1 2 3 4 5 7 8 1 RF Input Port 2 Grounding 3 RJ45 Web Management Interface 4 RS 232 5 Ou...

Страница 7: ...65VAC Connect the optical fibre with the optical output Make sure the connection is cleanded before use Connect the electric power and turn on the power switch The power supply LEDs are displaying the...

Страница 8: ...her errors expected RF Menu Press RF Gain Mode RF Gain Mode OMI Level OMI Level Normal OMI Adjust RF Attenuation OMI Adjust RF Attenuation OMI Adjust RF Attenuation OMI Adjust RF Attenuation OMI Adjus...

Страница 9: ...Current 53mA Laser Temp 25 3 Laser Cool Current 100mA Optical Wave Length 1310 00nm System Menu Firmware Version V1 0 Series Number System Temp 32 Power1 24 4V 24 4V Power1 5 4V 5 4V Power1 5 4V 5 4V...

Страница 10: ...ment Enter 192 168 1 1 into your web browser to get the following web interface The default password is admin After the login 5 items are displayed on the web interface Parameters Settings Information...

Страница 11: ...ich are displayed here can be changed AGC and MGC mode can be selected RF Attenuation from 0 12dB can be set when MGC mode is activated OMI can be set from 5 5dB 4 3 Information Here general informati...

Страница 12: ...10 03 Technical improvements changes in design printing and other errors expected 4 4 Network configuration Here the following parameters according to customer network can be set 4 5 Change password...

Страница 13: ...h the display output laser power is not correct Ring flange or test jumper connection is dirty Change the output laser power sensor Clean the connection Change the test jumper Test jumper connection m...

Страница 14: ...SM Optical Connector SC APC 6 2 RF characteristics Parameter Unit Value Frequency Range MHz 47 1002 RF Input Return Loss dBm 16 RF Input Level dB V 75 85 Flatness dB 0 75 CNR1 dB 50 CSO1 dBC 60 CTB1 d...

Страница 15: ...2017 10 03 Technical improvements changes in design printing and other errors expected 15 6 4 Outlines Drawing Dimensions are in mm...

Страница 16: ...Operation Instructions OTX 1310 10 Optical Transmitter 16 2015 12 04 AXING AG Swizzerland Technical data are subject to change errors and omissions excepted...

Отзывы: