3.8.
Device Redundancy (with MIS 1-11)
3.8.1.
Requirements
∂
A valid license (MIS 1-11) must be installed for the
backup device
∂
For device redundancy, two devices of the same type with identical configuration are a must. The easiest
way to get an identical configuration is to save the configuration data of the primary device and load it
into the backup device.
Log in to the
primary device
.
Under MAINTENANCE > SAVE
INITIALIZATION DATA TO FILE, click SAVE.
Save the Config.dat on your computer.
Log in to the
backup device
.
Select MAINTENANCE > UPLOAD SYSTEM
INITILIZATION DATA FROM FILE and select
the previously saved Config.dat
Click on UPLOAD.
The configuration is copied to the
backup
device
.
3.8.2.
Configuring Device Redundancy
Device redundancy is configured on the backup device.