background image

9

Common faults and solutions

If there are any abnormal phenomenon happened during range hood working, 

please stop using and unplug power supply and check the faults. Non 

professional personnel are not allowed to dismantle range hood. The common

faults and diagnosis are as follow:

Fault

Reason

Solution

Poor wire connect

Lamp is damaged
Poor connect between lamp and socket
The quartz lamp transformer burning out
Poor connect between plug and socket
Power cord break
Fuse of power board breaks
Thermal cutout of motor is working

Condenser burns

Motor burns
Faults of power board and control board 

Check the hanging is strong enough

The connecting pieces of the fixed screws 
are loose
Volute standing fixed screws are loose
Motor fixed screws are loose
Impeller installation is not in place
Impeller is damaged and balance piece is lost
Too much oil on filter
The air convection in the kitchen is too big 
or space sealing is too tight
Higher installation height 
Exhaust pipe is too long or too more turns
Outdoor wind is too strong

Repair or change wires

Change lamp

Repair or change

Change transformer

Repair or change

Change power cord
Change fuse

Wait for a while and turn on again

Change condenser
Change motor
Contact maintenance center

Hanging range hood firmly
Tighten screws
Tighten screws
Tighten screws
Install in place

Change impelle

r

Clean filter

Reduce air convection and open 
doors and windows moderately

Adjust t

o appropriate height

Install according to the manual
Non technical faults

Lamp is not on
Motor is running

Lamp is not on
Motor is not 
running

Lamp is on
Motor is not
running

Violent vibration, 
noise increases

Poor suction