Connection
Connector Function
1-2
Power supply 10-40VDC or 8-35VAC
3-4
Relay output
5-6
Not used
7-8
Timer input
Closure between terminals 7 and 8 means that
code 3
(CODE 3) is not working.
9-10
Exit button
Programming
To start the programming mode
After power-up, the programming mode starts automatically when the enclosure is closed. The pro-
gramming mode can then be activated by one of the following options:
l
Within 45 seconds after a valid access (with code or exit button) unlock, open and close the
enclosure.
l
With six-digit programming code.
In programming mode
CODE 1 , CODE 2 , CODE 3 and OPEN TIME flashes under the cor-
responding function buttons.
Determine programming code
1. Enter programming mode
2. Press A20.
3. Enter a six digit programming code
twice
. A valid entry is confirmed by a beep.
4. Exit programming mode by pressing B or wait for 30 seconds.
Add new code or change code
1. Enter programming mode
2. Press the function key for the code to be changed or added.
3. Enter the desired four-digit code.
4. Exit programming mode by pressing B or wait for 30 seconds.
2 (4)