Connection

Connector Function

1-2

Power supply 10-40VDC or 8-35VAC

3-4

Relay output

5-6

Not used

7-8

Timer input
Closure between terminals 7 and 8 means that

code 3

(CODE 3) is not working.

9-10

Exit button

Programming

To start the programming mode

After power-up, the programming mode starts automatically when the enclosure is closed. The pro-

gramming mode can then be activated by one of the following options:

l

Within 45 seconds after a valid access (with code or exit button) unlock, open and close the

enclosure.

l

With six-digit programming code.

In programming mode

CODE 1 , CODE 2 , CODE 3 and OPEN TIME flashes under the cor-

responding function buttons.

Determine programming code

1. Enter programming mode

2. Press A20.

3. Enter a six digit programming code

twice

. A valid entry is confirmed by a beep.

4. Exit programming mode by pressing B or wait for 30 seconds.

Add new code or change code

1. Enter programming mode

2. Press the function key for the code to be changed or added.

3. Enter the desired four-digit code.

4. Exit programming mode by pressing B or wait for 30 seconds.