the contents.

4.  To return to normal weight display (gross weight), 

remove any items from the weighing platform and 

press the

 TARE

 key again to re-zero the scale.

VII.  Using the Counting Feature

1.  Press the 

ON/OFF

 key to turn the scale on.

2.  Place a sample quantity of the items being weighed 

on the platform. This quantity should either be 25, 

50, 75, or 100 pieces.

3.  Once the weight is stable, press and hold the 

PCS

 

key to enter counting mode setup. 

4.  The current sample size will be displayed on the 

bottom right of the LCD.

5.  Press the 

MODE

 key to change it between 25, 50, 

75, or 100 and press 

PCS

 to confirm. The count 

will be displayed on the bottom right of the LCD. 

You may now add more items. As items are remove 

items and the count will update automatically.

VIII.  Calibration

Calibration and adjustment are performed at the factory. 

However, the weighing range can shift slightly during 

shipping. Also, due to changes in local acceleration of gravity 

around the world, adjustment is recommended when moving 

the scale from one location to another. To check calibration:

1.  Place the required calibration weight on the scale 

and note the displayed value.

2.  If the displayed value is not within acceptable 

tolerance (see chart on next page), adjustment is 

required.

Содержание ACP-200

Страница 1: ...American Weigh Scales ACP 200 200x0 01g ACP 500 500x0 1g User Manual ACPro Series Copyright 2010 American Weigh Scales Inc All rights reserved Rev 2 0...

Страница 2: ...efore performing calibration if available Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avoid...

Страница 3: ...lation 1 Before using the scale for the first time check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping...

Страница 4: ...back on it will default to the last unit used ACP 200 Units g gram dwt pennyweight ct carat gn grain ACP 500 Units g gram oz ounce ozt troy ounce dwt pennyweight VI Using the Tare Feature You can use...

Страница 5: ...s the MODE key to change it between 25 50 75 or 100 and press PCS to confirm The count will be displayed on the bottom right of the LCD You may now add more items As items are remove items and the cou...

Страница 6: ...e the required weight on the middle of the platform 4 The LCD will flash then flash the second required calibration weight Place the required calibration weight on the middle of the platform Skip this...

Страница 7: ...m capacity exceeded Remove the extra weight to avoid damaging the load cell 3 LO Batteries are low Replace the batteries 4 UNSE The scale is unstable Use the scale in a more stable position ACP 200 AC...

Отзывы: