Product Specifications 

Cable to Controller (for basic connections) 

·

 

5, 6 or 7 conductors (not twisted pairs), stranded, 22 AWG, color-coded insulation, overall 100% shielded  (Fig. 2) 

·

 

Length for Wiegand interface...................................Up to 500 feet 

Read Range (Metal Compensated) 

·

 

At 5 VDC.........Typically 6 inches (15 cm) 

·

 

At 12 VDC...........Typically 8 inches (20 cm) 

Characteristics 

·

 

Indoor and Outdoor ...................................................UL Listed

 

·

 

Operating Temperature Range .................................-35

°

 C to 65

°

 C (-31

°

 F to 150

°

 F)

 

·

 

Operating Humidity ...................................................0 to 95% non-condensing

 

Operating Parameters 

·

 

Excitation Frequency .................................................125 kHz 

·

 

Wiegand Output..........................................................Prox reader:  26 bits to 50 bits (as programmed in cards or tags) 

Keypad: 

26 bits only 

Certifications...............................................................................UL 294 Listed; FCC Part 15 certification; Industry Canada; CE 

 

Notes 

1.

 

Two readers at the same door may need to be separated physically or shielded from each other for best operation.  
Request Technical Reference issue on “back-to-back readers” from AWID. 

2.

 

When the yellow wire is not used, the beeper remains active and under the reader’s internal control. 

3.

 

The Beeper, Hold, and LED lines are logic levels.  

Never

 apply power to them.  They may be pulled to a low level         

(0 to 1.2 VDC) to enable their function.  They must float at a high level (3.6 to 5.0 VDC) when not used. 

4.

 

KP-6840 Readers have both Wiegand-protocol and RS-232 serial interfaces.  RS-232 data output applies to the card 
reader output only (not the keypad).  For information on RS-232, contact AWID’s technical support. 

5.

 

For additional information, please visit AWID’s web site (

www.awid.com

).  Send all technical support questions                                 

to 

[email protected]

.   Call AWID at 

1 -800-369-5533

 from 8:00 a.m. to 7:00 p.m. Eastern Time. 

6.

 

FCC Compliance:  This equipment has been tested and found to be in compliance with the limits for FCC part 15,    
Class A digital device.  These limits are designed to provide reasonable protection against harmful interference when   
the equipment is operated in a commercial environment.  This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with instruction manual, may cause harmful interference with radio 
communications.  Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 
      The users are prohibited from making any change or modification to this product.  Any modification to this product 
shall void the user’s authority to operate under FCC Part 15 Subpart A Section 15.21 regulations. 
      This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) This 
device may not cause harmful interference, and  (2) this device must accept any interference received, including 
interference that may cause undesired operation. 

7

 

Industry Canada Compliance:  Operation is subject to the following two conditions:  (1) This device may not cause 
harmful interference, and  (2) this device must accept any interference, including interference that may cause undesired 
operation of the device. 

 

 

 

          FIGURE 1:  SNAPPING OPEN THE COVER                      FIGURE 2:  WIRING DIAGRAM  (WIEGAND) 

Отзывы: