7 Maintenance
7.4.5
Notes on Cleaning
It is recommended for the device to be cleaned during maintenance.
Comply with the following safety notes prior to cleaning.
WARNING
Hazard from corrosive or aggressive cleaning agents!
There is a risk of death or severe physical injuries.
Adhere to the regulations and specifications in the safety data sheets for the cleaning
agents (e.g. vapors or hazardous substances).
Use personal protective equipment (e.g. protective gloves, safety shoes, safety
goggles).
Avoid excessive concentration of the cleaning agent.
Use only clean and chlorine-free water as a diluting agent.
Flush the device with plenty of clean water after cleaning.
Store cleaning agent in accordance with the applicable safety guidelines.
NOTE
Risk of damage to the device during cleaning!
The use of incorrect cleaning agent or sharp objects can damage the device.
The functional safety and reliability of the device may be compromised.
The cleaning agents must be approved for all materials of the device (e.g. seals,
bushings).
Do not use sharp objects (e.g. knives) or tools.
Cleaning in Assembled State:
As a basic rule, cleaning the device parts that are located in the interior of the container is NOT
necessary. Self-cleaning takes place during the cleaning process.
Cleaning is carried out by simply flushing the surfaces that come into contact with media (CIP cleaning).
Cleaning agents:
3% nitric acid max. +60 °C / +140 °F
3% caustic soda max. +80 °C / +176 °F
Cleaning after Removal:
Prior to cleaning, the device must have been removed from the container by an expert and
disassembled into its individual parts. The safety instructions in
section 7.1 Safety Notes for
Cleaning the device in a disassembled state can be carried out by instructed persons. After cleaning,
the device must be assembled, checked and reinstalled in the container by an expert (see
section 5.2
NOTE