If the hood does not have a power cable with a plug, or other means to disconnect it from the mains with

a separation between the poles, and with means to disconnect completely under category III overvoltage
conditions, it must be fitted with means to disconnect it from the mains in case of category III overvoltage
conditions according to the applicable legislations and regulations.

• Disconnection from the mains after installation should be accessible for the user. The power plug must
be  easily  accessible  or  if  not,  there  must  be  a  disconnection  switch  in  compliance  with  electrical
installation regulations.

• Take  special  care  when  perforating  walls  or  ceilings  and  ensure  that  there  are  no  hidden  electrical
cables,  pipes,  metal  beams,  etc.,  as  perforating  them  could  cause  great  damage,  short  circuits  or  the
transmission of noise and vibrations.

IMPORTANT: Before connecting the appliance to the mains, make sure the current is first turned

off (differential or circuit breaker on the general electrical panel of the house).

WARNING:  Always  disconnect  power  to  the  hood  before  cleaning  or  maintenance  operations,

either by unplugging it or disconnecting with the circuit breaker on the general electrical panel of
the  house.  Never  use  steam  or  high  pressure  devices  to  clean  the  hood  (electrical  safety
regulations), see section 8 on cleaning and maintenance

• The minimum distance between the surface of the cooktop and the lower edge of the hood must be 65
cm  if  the

extractor  hood

is  fitted  over  gas  cooker.  If  the  installation  instructions  of  the  gas  cooker

indicates a greater distance, this must be followed.

• Hood  and  conduit  installation  must  comply  with  regulations  on  ventilation  of  closed  spaces.  More
specifically, the exhausted air must not be led through a conduit that is used for exhausting fumes from
other appliances using gas or other fuels (central heating installations, etc.).

NB!

When the hood is in operation “in suction” at the same time as a heating system that depends

on  ambient  air  (gas,  oil,  coal  boiler,  chimney,  etc.),  take  special  care  to  avoid  the  hood  abosrbing  air
needed for combustion, this could cause dangerous accumulations of carbon monoxide in the premises or
home, which could be deadly. If the extractor hood is installed together with a combustion appliance such
as a boiler, chimney or local heating, the manufacturers of these appliances must be contacted to ensure
optimum and risk-free operation.

• Negative  pressure  in  the  premises  must  not  exceed  0.04  mbar.  This  will  allow  the  hood  to  operate  in
optimum  conditions.  To achieve  this,  it  is  necessary  to  have  a  permanent  entry  of fresh  air  to  avoid  air
stagnation,  it  is  recommended  to  have  a  ventilation  grille  for  this  purpose. Doors  and  windows  are  not
enough.

• Electrical power supply  must be stable and meet the electrical requirements of the appliance (see the
nameplate  of  the  appliance).  If  the  power  supply  is  unstable,  with  variations  in  voltage,  current,  surges
and cuts, electrical storms, etc., the hood could malfunction and even be damaged, in which case repairs
will not be covered by the guarantee. If any of these things happen, disconnect the hood and contact an
electrician or your electrical company to solve the problem.

• Improper and unauthorised handling of the hood, as well as modifying, cutting or perforating the body,
structure, motor or wiring of the hood are expressly forbidden. In case of any of the above, the guarantee
will be automatically void and the manufacturer will not be held liable for any possible harm or damages.

• The hood is an electrical appliance for fume extraction and must not be used as a support for objects or
utensils.

1. SAFETY INSTRUCTIONS

3

Содержание E-231

Страница 1: ...EN User and installation Manual 1 E 231 EXTERNAL MOTOR ...

Страница 2: ...ecessary into the products which will not alter their essential functional and safety characteristics When the appliance is delivered unpack it immediately and check that it is in good state by visual examination of the exterior If any fault or damage is observed do not install it and inform the dealer or installer immediately This hood has been designed for normal domestic use It must not be used...

Страница 3: ...austed air must not be led through a conduit that is used for exhausting fumes from other appliances using gas or other fuels central heating installations etc NB When the hood is in operation in suction at the same time as a heating system that depends on ambient air gas oil coal boiler chimney etc take special care to avoid the hood abosrbing air needed for combustion this could cause dangerous ...

Страница 4: ...GHT The recommended distance between the floor and the hood is a maximum of 2 50 m For greater heights consult our Technical Division POSITION OF THE HOOD The hood must be centred over the cooking area AIR INTAKE GRILLE To ensure optimum suction by the hood it is essential that the kitchen has a constant inward flow of air a ventilation grille at floor level is the perfect solution for this INSTAL...

Страница 5: ...5 100x180 OPCIONAL OPCIONAL EN OPTION OPTIONAL C x1 B x1 100x180 G x4 M8 E x4 Ø60 F x4 CONTENT Ø150 OR 100x180 A x1 D x1 ...

Страница 6: ...100x260 100x260 OPCIONAL OPCIONAL EN OPTION OPTIONAL CONTENT Ø200 OR 100x260 J x1 I x1 G x4 M8 E x4 Ø60 F x4 H x1 K x1 6 ...

Страница 7: ...Ø8 TOOLS NEEDLE 1300 790 750 1260 1005 135 48 DIMENSIONS 7 ...

Страница 8: ...INSERT SERIES OPTIONAL INSERT DIMENSIONS 8 ...

Страница 9: ...1 2 INSTALLATION 9 490 420 ...

Страница 10: ...4 3 INSTALLATION 22 G x4 10 ...

Страница 11: ...5 INSTALLATION 6 C x1 A x1 B x1 Ø150 100X180 Ø200 C x1 B x1 H x1 11 ...

Страница 12: ...INSTALLATION 7 8 E x4 F x4 12 ...

Страница 13: ...INSTALLATION OPTIONAL OUTPUT LONG SIDE FRONT ENGINE OUTPUT OPTIONS SERIAL OUTPUT 13 OPTIONAL UPPER OUTPUT TUBE Ø150 RECTANGULAR OUTPUT 100x180 ...

Страница 14: ...14 INSTALLATION OPTIONAL OUTPUT LONG SIDE FRONT ENGINE OUTPUT OPTIONS SERIAL OUTPUT RECTANGULAR OUTPUT 100x260 OPTIONAL UPPER OUTPUT TUBE Ø200 ...

Страница 15: ... EXTERNAL ENGINE L 15 ...

Страница 16: ...OFF ON 9 INSTALLATION ANNEX 10 16 ...

Страница 17: ...ower supply with switch OFF 2º Reconnect the power supply to the hood with switch ON 3º IMPORTANT When the hood has been reconnected to the mains supply before 20 seconds have passed press the LIGHT key with the remote control pointing to the hood 4º The hood will light up indicating that the process was correct the transmission code of remote control was registered by the electronic unit of the h...

Страница 18: ...PUSH PUSH MAINTENANCE ALUMINIUM FILTER ACTIVATED CARBON FILTER FCLR WASHABLE AND RETRIGGERABLE OPTIONAL LED LIGHTING AND FEATURES 18 ...

Страница 19: ...A MAINTENANCE LED LIGHTING AND FEATURES P 6 48W Long 765mm P 6 48W T 4500K A 12VDC 19 ...

Страница 20: ...Award Appliances NZ Limited E mail sales award co nz www awardappliances co nz ...

Отзывы: