6.OSD - Alarm Setting
Some products may not be available in your country, please contact our distributor for more details
Some products may not be available in your country, please contact our distributor for more details
7.PROTOCOL SETTING
19
ALARMS
RESUME
OFF
RESET DELAY
020
ALARM CONTACT
N/C
ALARM SETTING
BACK
EXIT
Alarms
RESUME:
Continues the previous function of the
camera before the alarm was activated.
RESET DELAY:
How long the camera stays in Alarm
mode.
ALARM CONTACT:
Setting between N/C (normal
Close) or N/O (normal Open).
ALARM NUMBER:
Ranging from 1-7.
ALARM ACTION:
Setting for PRESET, SCAN, TOUR,
PAT 1-4, or NONE, if the camera’s alarm function is
activated.
ACTIVATE AUX:
Setting Alarm Output, when alarm is
activated. Select between AUX1, AUX2 (not
connected) or BOTH.
ALARM SETTING
ALARM NUMBER
001
ACTION
TOUR
ACTIVATE AUX
AUX1
BACK
EXIT
ALARM
AUX2
AUX1
ALARMAS
7
6
5
4
3
2
1
GND
Alarm input 1to 7
Common port
Alarm output 1
Alarm output 2
Alarm Connection
on Backboard
Sw1
Sw2
Protocol Setting
This procedure is needed if a connection of the
telemetric control with the keyboard device is
desired. You need to setup the dome address and
protocol settings.
The speed dome support multiple communication
protocols. The settings can be changed by
rearranging the DIP-Switches on the rear side of
the connector board as illustrated.
Please use the following table for detailed
information.
Baud rate
DIP 7
DIP8
2400 bps
0
0
4800 bps
1
0
9600 bps
0
1
19200 bps
1
1
SW 1:
Represents the dome’s address in binary form.
Please refer to the list on the next pages for
reference.
Used for protocol settting and baud rate.
SW 2:
DIP 1 to 6 : Protocol settings
DIP 7 and 8:Baud rate settings
B02
0 0 1 1 0 0
DIAMOND
1 0 0 1 0 0
HUNDA
1 0 1 1 0 0
KALATEL
0 1 0 1 0 0
LILIN
1 1 0 1 0 0
MOLYNX
0 0 1 0 0 0
PANASONIC
1 1 1 0 0 0
PELCO (D/P)
1 0 0 0 0 0
PHILIPS
0 0 0 0 0 1
SAE
0 1 0 0 0 0
SAMSUNG
0 0 0 1 0 0
SANTACHI
0 1 1 0 0 0
UNIVISION
0 1 0 0 0 1
VCL
1 1 0 0 0 0
VICON
1 0 1 0 0 0
AD
0 0 1 1 0 0
Protocol / DIP
1 2 3 4 5 6