Avtech IR Done Camera Скачать руководство пользователя страница 4

 

 

CAMERA PARAMETERS 

On the DVR, right-click to show the main menu, and go to “ADVANCED CONFIG” 

 “DCCS”. 

In “DCCS”, select the channel which connects this camera, and click “SETUP” to enter the menu of camera 

parameters. 

ADVANCED CONFIG 

 

CAMERA 

CH1 CH2 CH3 CH4 

 

DETECTION 

MENU SETUP 

ALERT 

 

 

NETWORK 

 

 

DISPLAY 

 

 

RECORD 

 

 

DCCS 

 

 

NOTIFY 

DEVICE AVT503S 

MULTICASTING 

CONNECTION OK 

 

 

EXIT  

 

Item 

Description 

BRIGHTNESS 

Click the current value to manually adjust the brightness of the image. The higher the value, 
the brighter the image. 

CONTRAST 

Click the current value to manually adjust the contrast of the image. The higher the value, 
the higher the contrast ratio. 

HUE 

Click the current value to manually adjust the hue of the image.   

SATURATION 

Click the current value to manually adjust the saturation of the image. The higher the value, 
the more saturated the image. 

CAMERA GUARD 

Enable “GUARD LOCK” to temporarily disable the pan function of this camera and fix the 
camera surveillance area.   
For details, please refer to the section “

CAMERA GUARD

”. 

SEQUENCE 

Configure a sequence group for area patrol.   
For details, please refer to the section “

MOTORIZED PAN AND SEQUENCE SETUP

”.

 

 

WHITE BALANCE 

Process the current image to retain color balance over a color temperature range. 
The options are: Auto, 2500K, 3200K, 4200K, 5800K & 9500K. 

SHARPNESS 

Sharpness enhances the clarity of image detail by adjusting the aperture and sharpening the 
edges in the pictures.   
Hold and drag the slider to adjust the level of sharpness. The higher the value, the sharper 
the image. 

SLOW SHUTTER 

Slow shutter is used to increase the exposure time to get clearer image, for example, at night.
The options are: AUTO, 1/15 and 1/6. 

MIRROR 

Select “ON” to rotate the images horizontally based on your installation situation when 
necessary. 

FLIP 

Select “ON” to rotate the image 180° when necessary. 

DENOISE 

Click and drag the slider to adjust the level from 0 ~ 10 to decrease the noise shown in the 
dark environment. 

EXPOSURE VALUE 

Drag the slider to adjust the exposure level from 0 ~ 4. 

WIDE DYNAMIC RANGE 

Wide Dynamic Range (WDR) is used when users need to increase image recognizability in 
overexposure and dark areas.   
The options are: LOW / MIDDLE / HIGH / OFF 

FIXED SHUTTER 

Shutter Speed is a function that can adjust the duration of the electronic shutter to produce 
optimum image quality. Select the shutter speed suitable for your environment. 

DEFOG 

Select “ON” to enable the defog function in poor weather conditions such as fog, smog or 
smoke. The captured image can be improved. 

IR CONTROL 

Select “Auto” to automatically enable IR LEDs at night or in the dark environment, or “OFF” to 
disable this function. 

IR TURN ON LEVEL 

Select the level for IR light to activate. 0 ~ 20 

IR EXTEND TIME 

Configure from 0 ~ 60 seconds to delay the switch of the IR mode at night, or select “0” to 
disable this function. 
This is used for the environment where the light condition may change suddenly and usually 
last for a short time, for example, the entrance of a parking lot. It may cause the day & night 
mode switching constantly and damage the camera.   
With this function, the camera will delay the mode switch at night since the light change is 
temporary and unnecessary to pay attention. 

RESET DEFAULT 

Click to reset all camera settings to their default values. 

REBOOT THE SYSTEM 

Click to reboot the camera if necessary. 

 

Содержание IR Done Camera

Страница 1: ...to constitute a risk of electric shock to persons This exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance ROHS Announcement All lead free products offered by the company comply with the requirements of the European law on the Restriction of Hazardou...

Страница 2: ...nce PACKAGE CONTENT IR camera User manual Accessory pack DIMENSIONS Dimensional Tolerance 5mm SPECIFICATIONS Pick up Element 1 2 8 SONY CMOS image sensor Number of Pixels 1936 H 1096 V Video Frame Rate 1080P 30fps 1080P 25fps Min Illumination 0 1 Lux F1 8 0 Lux IR LED ON S N Ratio More than 48dB AGC OFF Shutter Speed 1 10 000 1 7 5 Slow shutter Lens f3 6mm F1 8 Lens Angle 87 Horizontal 46 Vertical...

Страница 3: ..._installation_sticker pdf For cabling behind the ceiling or wall mark the location for one more hole for the camera cable to go through For cabling along the ceiling or wall do as indicated below for the cable to go through Step 4 Fix the camera to the ceiling or wall with the supplied screws Step 5 Connect your camera to power Step 6 Tilt and rotate the lens itself to adjust the position and view...

Страница 4: ...ncrease the exposure time to get clearer image for example at night The options are AUTO 1 15 and 1 6 MIRROR Select ON to rotate the images horizontally based on your installation situation when necessary FLIP Select ON to rotate the image 180 when necessary DENOISE Click and drag the slider to adjust the level from 0 10 to decrease the noise shown in the dark environment EXPOSURE VALUE Drag the s...

Страница 5: ... of the PTZ camera Preset point Click to enter the PTZ preset point you want to see To pan the camera Click to move the camera manually To set a sequence group Step1 Click to display the preset point panel and click to go to the setting panel Step2 Click to move to the point you want to configure as a preset point and click the numbering you want to appoint for this point Then wait till you see co...

Страница 6: ...NSPEED No2 01 No2 60 0 0 255 No3 02 No4 60 0 0 255 No4 03 No5 60 0 0 255 No5 04 No1 60 0 0 255 No6 05 No3 60 0 0 255 No7 No8 No9 No10 No11 No12 No13 No14 EXIT ACTIVE TIME MINUTES Select how long the area patrolling lasts in minute The options are 2 3 and 5 DWELL TIME Select the time in second after which to move to the next point The time ranges from 3 to 60 PAN SPEED Select how fast to move the c...

Страница 7: ...n select the channel which connects this camera and click SETUP to enter the menu of camera parameters ADVANCED CONFIG CAMERA CH1 CH2 CH3 CH4 DETECTION MENU SETUP ALERT NETWORK DISPLAY RECORD DCCS NOTIFY DEVICE AVT503S MULTICASTING CONNECTION OK EXIT Step2 Select CAMERA GUARD and enable this lock function Then configure the timeout after which the camera will be fixed to the current point and any ...

Страница 8: ...Step4 Return to the address book of EagleEyes and enable Guard The camera will fix at the point after the time specified in Step2 unless the Guard status is disabled ...

Отзывы: