WITH NO DUT
If a piece of busbar wire is installed in the axial pocket, the basic speed of the test
socket may be judged. With I
F
= +100 mA and I
R
= -100 mA, a 10%-90% switching time
of 709 ps observed:
The inductance of the busbar and the socket degrades the transition time of the pulse
from the mainframe. If the mainframe OUT is fed directly into an oscilloscope
(bypassing the test jig), transition times of less than 200 ps are observed:
47
Содержание AVR-EB2A-B
Страница 32: ...Or shown in a closer view The remaining photos shown the different types of SQMELF packages installed 32 ...
Страница 44: ...The installed DUT is shown below 44 ...
Страница 46: ...The installed DUT is shown below 46 ...
Страница 48: ...It is still below 300 ps at 10 mA 10 mA as well 48 ...
Страница 56: ...PCB 158R4 LOW VOLTAGE POWER SUPPLY ...
Страница 65: ...TEST JIG WIRING AVX CA AXPOST ...
Страница 67: ...TEST JIG WIRING AVX CA SOD123 QTKA ...
Страница 69: ...TEST JIG WIRING AVX CA SOT23B ...
Страница 70: ...CUSTOMIZED DAUGHTERBOARD AVX CA SOT23B ...
Страница 71: ...PERFORMANCE CHECK SHEET 71 ...