background image

AVAILABLE OPTIONS

The AVIR-3-B is available with several options:

-EA Option: the amplitude can be controlled by an externally generated 0 to +10V 
analog control voltage.

-M Option: a monitor output is provided.

-OS Option: an externally generated DC offset can be added to the output.

-R5 Option: A rack mounting kit is available. The "-R5" rack mount kit may be installed 
after first removing the one Phillips screw on the side panel adjacent to the front 
handle.

6

Содержание AVIR-3-B

Страница 1: ...13901 A V T E C H E L E C T R O S Y S T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 info avtechpulse com http www avtechpulse com Tel 888 670 8729 USA Canad...

Страница 2: ...ace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty is the ext...

Страница 3: ...E LICENSING 10 INSTALLATION 11 VISUAL CHECK 11 POWER RATINGS 11 CONNECTION TO THE POWER SUPPLY 11 PROTECTION FROM ELECTRIC SHOCK 12 ENVIRONMENTAL CONDITIONS 13 LABVIEW DRIVERS 13 FUSES 14 AC FUSE REPL...

Страница 4: ...ECTROMAGNETIC INTERFERENCE 32 MAINTENANCE 33 REGULAR MAINTENANCE 33 CLEANING 33 TRIGGER DAMAGE 33 WIRING DIAGRAMS 34 WIRING OF AC POWER 34 WIRING OF DC POWER 35 PCB 158R4 LOW VOLTAGE POWER SUPPLY 36 P...

Страница 5: ...is a highly flexible instrument Aside from the internal trigger source it can also be triggered or gated by external TTL level signals A front panel pushbutton or a computer command can also be used...

Страница 6: ...enerated 0 to 10V analog control voltage M Option a monitor output is provided OS Option an externally generated DC offset can be added to the output R5 Option A rack mounting kit is available The R5...

Страница 7: ...lse trigger via computer command Variable delay Sync to Out 0 to 1 0 seconds for all trigger modes including external trigger Sync output 3 Volts 100 ns will drive 50 Ohm loads Connectors Out SMA Trig...

Страница 8: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Страница 9: ...tion of conformity is issued under the sole responsibility of Avtech Electrosystems Ltd Specifically products manufactured do not contain the substances listed in the table below in concentrations gre...

Страница 10: ...9 have been made Requirements for WEEE compliance may include registration of products with local governments reporting of recycling activities to local governments and financing of recycling activiti...

Страница 11: ...mal single phase supply CONNECTION TO THE POWER SUPPLY An IEC 320 three pronged recessed male socket is provided on the back panel for AC power connection to the instrument One end of the detachable p...

Страница 12: ...erators are prevented access and or are insulated from every connection point In some cases connections must be exposed to potential human contact Operators must be trained to protect themselves from...

Страница 13: ...C decreasing linearly to 50 relative humidity at 40 C 5 Mains supply voltage fluctuations up to 10 of the nominal voltage 6 no pollution or only dry non conductive pollution LABVIEW DRIVERS A LabVIEW...

Страница 14: ...the fuses on the rear panel are shown in the figure below AC FUSE REPLACEMENT To physically access the AC fuses the power cord must be detached from the rear panel of the instrument The fuse drawer ma...

Страница 15: ...Nominal Mains Voltage Rating Case Size Recommended Replacement Part Littelfuse Part Number Digi Key Stock Number 1 2 AC 100 240V 0 5A 250V Time Delay 5 20 mm 0218 500HXP F2416 ND 3 DC N A 1 0A 250V Ti...

Страница 16: ...conds after which the instrument will attempt to re enable the output i e light green for about 1 second If the overload condition persists the output will be disabled again i e light yellow for anoth...

Страница 17: ...numeric parameters is displayed this increases the setting by a factor of ten 10 If one of the adjustable numeric parameters is displayed this decreases the setting by a factor of ten If one of the ad...

Страница 18: ...e instrument This input can be either active high or active low depending on the front panel settings or programming commands The instrument triggers normally when this input is unconnected When set t...

Страница 19: ...nsing to work A standard Linux agetty process is used to implement serial control internally See the Programming Manual for B Instruments for more details on RS 232 control 8 Network Connector This Et...

Страница 20: ...set to a positive value the SYNC pulse precedes the OUT pulse When the delay is set to a negative value the SYNC pulse follows the OUT pulse These pulses are illustrated below assuming internal trigg...

Страница 21: ...ment controls the trigger frequency and generates the clock internally External Trigger the instrument is triggered by an external TTL level clock on the back panel TRIG connector Manual Trigger the i...

Страница 22: ...sed by a TTL level signal on the rear panel GATE connector The instrument can be set to stop triggering when this input high or low using the front panel gate menu or the appropriate programming comma...

Страница 23: ...nductor via a high quality RF inductor Do not exceed 50V 250 mA MONITOR OUTPUT M OPTION The monitor output provides an attenuated replica 20 dB down of the voltage on the main output The monitor outpu...

Страница 24: ...rned off when the instrument is not in use In the case of failure the switching elements are easily replaced following the procedure described in a following section DO NOT EXCEED 20 kHz The output st...

Страница 25: ...roper operation The output stage may be damaged if the output is not terminated into a 50 load The AVIR 3 B output may be observed using either a high speed sampling oscilloscope or a slower real time...

Страница 26: ...ed to terminate the output c The SYNC output channel provides TTL level signals approximately 0 and 3V To avoid overdriving the TRIG input channel of some sampling oscilloscopes a 20 dB attenuator sho...

Страница 27: ...appear Rotate the ADJUST knob until the delay is set at 100 ns c The arrow pointer should be pointing at the Normal choice If it is not press MOVE until it is d Press CHANGE to return to the main menu...

Страница 28: ...may need to adjust the delay setting to a value more compatible with your sampling oscilloscope Repeat step 4 if required You may also need to adjust the sampling scope controls d Rotate the ADJUST k...

Страница 29: ...turns on the output For triggering a single event this sequence would be more appropriate rst resets the instrument trigger source hold turns off all triggering pulse width 50 ns sets the pulse width...

Страница 30: ...value DCYCle numeric value HOLD WIDTh DCYCle DELay numeric value GATE TYPE ASYNC SYNC LEVel HIgh LOw SOURce VOLTage LEVel IMMediate AMPLitude numeric value EXTernal PROTection TRIPped query only STAT...

Страница 31: ...Nual HOLD IMMediate CLS no query form ESE numeric value ESR query only IDN query only OPC SAV 0 1 2 3 no query form RCL 0 1 2 3 no query form RST no query form SRE numeric value STB query only TST que...

Страница 32: ...factory for repair Service is to be performed solely by qualified service personnel Caution High voltages are present inside the instrument during normal operation Do not operate the instrument with t...

Страница 33: ...s recommended TRIGGER DAMAGE The rear panel TRIG input used in the external trigger mode is protected by a diode clamping circuit However the protection circuit is not foolproof and it is possible for...

Страница 34: ...U X A K Y B R O Y G T O LCD T O PCB108 T O ENCODER T O LCD 104D BD2 PCB104D KEYPADBOARD B UNITS ONLY Chassisgroundpost G1 G2 B1 RED G4 G3 L N G X2 CORCOM6EGG1 2 POWERENTRY M ODULE 1 1b 1a 2 2b 2a X1 P...

Страница 35: ...CHSGND 340VFIXEDTOPG A GNDTOPG A CHSGND 225VFIXEDTOPG B GNDTOPG B CHSGND 15 O Y 100K O Y NOTUSED 3 9K 5K HORZ PO T NOTUSED 0 TO 235VTOPG B GNDTOPG B OP1B AM P OR C AMPPOT 100OY 220K O Y NOTUSED ZEROO...

Страница 36: ...PCB 158R4 LOW VOLTAGE POWER SUPPLY...

Страница 37: ...PCB 235B HIGH VOLTAGE DC POWER SUPPLY...

Страница 38: ...2015 ddb Documents Panelbrd prj PANELTOP LEVELSCHEMATIC 1 2 3 4 5 6 7 8 9 10 J5 Amp 54999 10 1 10 pin straight head er I2C_INT SC L SDA GND VC C SINGLE PULSE BACKLIGHT ENCODER ENCODER S CH I2C_INT SC...

Страница 39: ...UST HAVE A IN P N VC C 1A 1B X2 82 101 71 1 b utton keypad 1 2 U4 A MM74HC 14N 11 10 U1 E MM74HC 14N SINGLE PULSE VC C VC C C1 0 2 2uF C1 1 2 2uF C1 2 2 2uF C9 2 2uF C7 2 2uF C6 2 2uF C1 2 2uF 3 4 U4...

Страница 40: ...DA SC L VC C VC C GND VC C VC C C5 0 1uF 1 2 U1 A MM74HC 14N 13 12 U1 F MM74HC 14N 5 6 U1 C MM74HC 14N PAD3 LED PAD4 LED X3 4 40 MOUNT X1 4 40 MOUNT X9 4 40 MOUNT X8 4 40 MOUNT 3 4 U1 B MM74HC 14N LC...

Страница 41: ...GATE 23 EXTTRIG 24 SYNC OUT 25 M AINOUT 26 5VON OFF 27 15VON OFF 28 OUT SYNC VSPARE VPRF GATE 24 V GND TR IG AUX GND VF NO C NC SW NO C NC AMP LAN O LIM EX 295E BD2 PCB295E HVVAR HVFIXED OUT IN1 GND G...

Страница 42: ...PERFORMANCE CHECKSHEET 42...

Отзывы: