SPECIFICATIONS
Model
1
:
AVG-4A-B
Amplitude
2,7,8
:
90 - 600 V
Pulse width, measured at:
≤ 5 ns, at 20%
Rise time (20%-80%):
≤ 1.5 ns
Fall time (80%-20%):
≤ 3 ns
PRF:
0 to 10 kHz
Required load:
50Ω
7
Polarity
3
:
Positive or negative or both (specify)
GPIB & RS-232 control
1
:
Standard on -B units.
Ethernet port, for emote
control using VXI-11.3, ssh,
telnet, & web:
Included. Recommended as a modern alternative to GPIB / RS-232.
http://www.avtechpulse.com/options/vxi
for details.
Settings accuracy:
Not specified / not calibrated.
Verify the output parameters with a calibrated oscilloscope.
LabView Drivers:
http://www.avtechpulse.com/labview
for availability and downloads
Propagation delay:
≤ 50 ns (Ext trig in to pulse out)
Jitter:
± 100 ps (Ext trig in to pulse out)
DC offset:
-OS option
4
: Apply required DC offset (± 50 Volts, 250 mA DC max)
to rear-panel solder terminals
Trigger modes:
Internal trigger, external trigger (TTL level pulse, > 10 ns, 1 kΩ input impedance),
front-panel “Single Pulse” pushbutton, or single pulse trigger via computer command.
Variable delay:
0 to 1.0 seconds, for all trigger modes (including external trigger)
Sync out:
+ 3 Volts, 200 ns, will drive 50 Ohm loads.
Gate input:
Active high or low, switchable. Suppresses triggering when active.
Monitor output:
Optional
5
: Provides a 20 dB attenuated coincident replica of main output
Connectors:
Out: SMA
9
, Trig, Sync, Gate: BNC
Dimensions (H x W x D):
100 mm x 430 mm x 375 mm (3.9” x 17” x 14.8”)
Power:
100 - 240 Volts, 50 - 60 Hz
Chassis material:
Cast aluminum frame & handles, blue vinyl on aluminum cover plates
Temperature range:
+5°C to +40°C
1.
-B suffix indicates IEEE-488.2 GPIB and RS-232 control of amplitude, pulse width, PRF and delay (see
http://www.avtechpulse.com/gpib
).
2.
For operation at amplitudes of less than 20% of full-scale, best results will be obtained by setting the amplitude near full-scale and using external attenuators on the
output.
3.
Indicate desired polarity by suffixing model number with -P or -N (i.e. positive or negative) or -PN for the dual polarity option. AVX-1 transformer may be used to
invert polarity.
4.
For DC offset option suffix model number with -OS.
5.
For monitor option add suffix -M.
6.
Falls to 180V for PRF above 10 kHz.
7.
A 50 Ohm load is required. Other loads may damage the instrument. Consult Avtech ([email protected]) if you need to drive other load impedances.
8.
Maximum amplitudes are for positive outputs only. The maximum negative amplitude for -N and -PN units will be approximately 10% lower, due to the use of an internal
inverting transformer.