OM-ECOARCH 21
Periodic Maintenance
1. Baffle Filters
Filters should be removed and cleaned at least weekly, depending on hours of operation.
Filters may be cleaned by soaking in a strong detergent solution or running thru a
dishwasher. When replacing, make sure filters and handles are running vertically, and
filters are seated properly.
2. Modular Grease Extractors
Modules should be removed and cleaned at least weekly, depending on hours of
operation. Modules may be cleaned with a brush and a strong detergent solution or
run thru the dishwasher. When replacing modules, make sure they are seated properly.
3. Grease Trough
Should be checked weekly for grease build up and cleaned with strong detergent if
necessary.
4. Grease Collection Receptacle
Should be emptied at least once a day and cleaned daily with a strong detergent.
5. Hood Canopy
A. Inside hood canopy should be wiped down as needed. The area at the exhaust
intake openings should be wiped down daily.
B. Inspect inside of extraction chamber at least weekly to insure proper cleaning and
that the trough and access door are free of foreign matter.
6. UV Preventative Maintenance
Clean the UV lamp at the same time the grease extractors are being cleaned (or daily),
wipe down the UV lamp exterior using a dry towel and a non-detergent cleaning agent
such as sanitizing solution or white vinegar.
IMPORTANT: Do not allow cleaner to run into lamp fittings or socket enclosures.
IMPORTANT: UV System will not work properly without daily cleaning of the UV lamp.
WARNING
ELECTRICAL SHOCK HAZARD! DISCONNECT
POWER BEFORE SERVICING. REPLACE ALL
PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH
OR ELECTRICAL SHOCK.
CAUTION
MAKE SURE ALL COOKING EQUIPMENT, THE
EXHAUST HOOD AND UVC EXHAUST AIR
CLEANER HAVE BEEN TURNED OFF AND
ALLOWED TO COOL. HOT EQUIPMENT CAN
CAUSE BURNS.
CAUTION
USE STEP LADDER OR OTHER STABLE
PLATFORM TO PROVIDE EASY ACCESS TO
THE INTERIOR OR THE UVC LAMP CABINET.
DO NOT STAND ON COOKING EQUIPMENT
TO SERVICE THE UVC. FALLS CAN CAUSE
SERIOUS INJURIES.
Содержание ecoarch
Страница 7: ...OM ECOARCH 7 Installation Instructions Figure 5...
Страница 8: ...8 OM ECOARCH Installation Instructions Figure 5 Continued...
Страница 10: ...10 OM ECOARCH Installation Instructions Figure 6a RELAY BOX BALLAST BOX...
Страница 11: ...OM ECOARCH 11 Installation Instructions Figure 6b...
Страница 12: ...12 OM ECOARCH Installation Instructions Figure 6c...
Страница 15: ...OM ECOARCH 15 Installation Instructions Figure 7 FOR CONTROL PANEL IF PROVIDED...