- 7 -
TERMINAL BLOCK
+
Positive power
DA - DB
DA / DB RS485 serial connection port
-
Negative power
T1
Manages the input link to zone n° 7 and / or open collector output (OC 7)
T2
Manages the input link to zone n° 8 and / or open collector output (OC 8)
T
Tamper input (TAMPER) balanced with reference to negative.
-
Negative
JUMPER
S1
1 - 2
2 - 3
OPEN
TAMPER Button: DISABLED - Input T: DISABLED (
ALLOW FREE ENTRY T)
TAMPER Button: ENABLE - Input T: DISABLED (
ALLOW FREE ENTRY T)
TAMPER Button: ENABLE - Input T: ENABLED
DIP SWITCH
SAT1 SAT2
SAT3
SAT4
SAT5
SAT6
SAT7
SAT8
SAT9 SAT10 SAT11 SAT12 SAT13 SAT14 SAT15
SAT16
DIP 1
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
DIP 2
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
Off
Off
On
On
DIP 3
Off
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
On
On
On
On
DIP 4
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
On
On
On
On
DIP 5
DIP 6
Not used
DIP 7
Off
Disable the input link to zone n° 7 e zone n° 8
On
Enable the input link to zone n° 7 e zone n° 8
DIP 8
Not used
LED MULTICOLOR
WHITE LED
It lights up when the antenna A is receiving
GREEN LED
It lights up when the antenna B is receiving
RED LED
It lights up when is in transmission
SENSOR PROGRAMMING IF COMBINED WITH XTREAM CONTROL PANELS
Parameter 1 Enab. accelerom.:
setting to “YES” enables reporting of the strain and of disorientation of the radio sensor as TAMPER
Parameter 2 Low power mode:
setting to “YES” enables the “Low consumption” of the radio sensor battery
Parameter 3 Antimask sensit.:
it is possible to adjust the sensitivity of the Antimask present in the sensor by setting
4
-
100
% (Maximum) or
3
-
75
% or
2
- 50% . By setting to
1
-
OFF
the Antimask is not active
Parameter 4 IR Reduc. Sensit.:
setting to “YES” enables a reduction in sensitivity of the infra-red
Parameter 5 IR Sig. integrat.:
setting “Double pulse” activates a further reduction of the sensitivity of the infra-red
Parameter 6 MW Sensitivity:
it is possible to adjust the microwave sensitivity present in the sensor by setting
1
-
100
% (max) or
2
-
75
% or
3
-
50
% or
4
-
25
%
Parameter 7
Enab. IN1 term.:
in the radio sensor WIC 4 / WIC 4 Plus, setting to “YES” enables functioning of the terminal input IN1
NOTE:
In case of double channel, configuration of both the sensors must be made exclusively on the one with the lowest
address
Parameter 8 Puls. inert/SW-AL:
in the WIC 4 / WIC 4 Plus radio sensor, it is possible to adjust the number of pulses of the input alarm IN1.
1 = High sensitivity - 16 = Low sensitivity
Parameter 9 Vibration enable:
in the WIC 4 / WIC 4 Plus radio sensor, setting to “YES” enables the integrated accelerometer “vibration” function
.
Parameter 10 Vibration sens.:
in the WIC 4 / WIC 4 Plus radio sensor, it is possible to adjust the sensitivity of the accelerometer present in
the sensor.
1 = High sensitivity - 8 = Low sensitivity
Parameter 11 Vibration pulses number:
it is possible to adjust the number of pulses of the Accelerometer present in the sensor.
1 = Very
sensitive - 16 = Little sensitive
SIRENA RADIO PROGRAMMING IF COMBINED WITH XTREAM CONTROL PANELS
Parameter 1 Enab. accelerom.:
setting to “YES” enables reporting of the strain and of disorientation of the radio siren as TAMPER
Parameter 2 Max time alarm:
One minute/three minutes
Parameter 3 Sound level:
there is a choice of 8 Levels.
The values are relative to the sound level of both the Main Sound and the Alternative
Sound.
1 is the Maximum and 8 is the Minimum
.
Parameter 4 Principal sound tone:
it is possible to select one of 8 tones for the Principal Sound
Parameter 5 Power supply type:
select the type of power supplied to the siren between
1
- Battery 6V or
2
- Power supply 12V + Battery
Parameter 6
Tamper active siren:
setting to “NO”, in case of tamper / antitear opening the siren transmits the event and sounds according
to the schedule of the combined central unit setting to “YES”, if the tamper / tear-off is opened, the siren transmits the event and
sounds autonomously for the time set “Max. sound “or based on commands sent from the combined control panel.
Parameter 7 Flash on / off:
enables the siren flash to flash the on / off of the central office;
Parameter 8 Vibration enable:
setting to “YES” enables the integrated accelerometer “vibration” function.
Parameter 9 Vibration sens
.
:
it is possible to adjust the sensitivity of the accelerometer present in the siren.
1 = High sensitivity - 8 = Low
sensitivity.
Parameter 10 Vibration pulses number:
it is possible to adjust the number of pulses of the Accelerometer present in the siren.
1 = Very
sensitive - 16 = Little sensitive