RS-485 Network Connection
Execute the following steps to connect multiple cameras to RS-485:
1.
Attach the cameras to a 2-wire twisted pair bus (maximum length 1200m) that is terminated at
both ends with a 120Ω-impedance resistor.
2.
Ensure that the maximum distance from the bus t of the camera or controller is 5m. If you use only
ONE camera, the impedance resistor is not needed.
Figure 12: RS-485 Network Connection Diagram
Connecting via LAN
Avonic IP cameras can be controlled by any device using the Visca over IP protocol (see the command list in
Appendix A - VISCA Settings and Command List
).
Settings
By default, the IP address of the camera is "192.168.5.163" with "admin" for both the username and password.
The control parameters for the CM7x-IP cameras are as follows:
• IP Address: 192.168.5.163
• Username: admin
• Password: admin
• TCP or UDP port: 1259
IP (Network) Connection
Execute the following steps an Avonic PoE camera to a LAN:
1.
Use a standard (PoE) switch. If the unit is simultaneously connected to both PoE and its own power
supply, the power supply will take priority. If the power supply is disconnected when PoE is present,
the camera will remain operational without interruption.
2.
Ensure that addressing is done via IP. When using VISCA over IP, the 'x' in all the '8x' addresses is
always '1', where the Visca address in a Visca over IP environment is always 1. (See
VISCA Settings and Command List
for more information.)
Figure 13: IP Network Connection Diagram
19