VISCA over IP commands
The Avonic CM60-IP camera is implemented with a TCP server. The TCP port number is 5678 by
default and can be altered in the WebGUI. Once the connection between client and server is set up,
the client will be able to send PTZ commands to the server. The server then parses and executes the
PTZ command.
The Avonic IP Camera has also implemented a UDP server. The UDP port number is fixed on 1259.
Once the connection between client and server is set up, the client will be able to send PTZ
commands to the server. The server then parses and executes the PTZ command.
The VISCA over IP command list is based on the VISCA protocol. Not all VISCA commands are
implemented.
The PTZ Command format is according to the definition of the VISCA protocol. The VISCA address of
the camera is set to 1 by default and can be changed in the WebGUI. As all cameras are uniquely
identified by their IP address, all VISCA addresses of the cameras that are controlled over IP do not
necessarily have to be unique.
Default settings:
TCP port
5678
UDP port
1259
VISCA address
1
The commands are as follow:
Camera return commands
x= Camera Address
y= Socket Number