14 PMIC Version Check and Update
Another capability that we have is to check the version of the programming inside the PMICs.
As described in the Ultra96-V2 PCN19003, there have been multiple releases of the PMIC
programming files. This is also described in this blog.
You can now check the version of your PMIC programming and update to the latest version if
you want.
WARNINGS!
The Infineon PMICs only have 26 programming locations. Each time the devices are
reprogrammed, another location is consumed. Use with caution!
If you accidentally program a device with the wrong file (like the 0x14 device with the 0x13 file or
vice versa), you WILL damage your board, and it will NOT be covered under warranty. You
must program the
correct file
to the
correct device
.
Permanent damage will occur otherwise.
14.1 PMIC Version Checking
1. Change directories to the location of the PMIC programmer and list the config files.
# cd ~/pmic-prog
# ls -l pmic-configs/
Figure 31 – PMIC Config Files
The naming convention for the files is as follows.
<board>_<device>_<channel>_<datecode in YYMMDD>
<board> U96V2
<device> 5401 or 38060
<channel> 0x13, 0x14, or 0x15
<datecode> 191030 = 2019, October 30