Operator Manual, Supercharger 60
R3.0
Page 46 of 62
•
Set the Cell Selector at 20, connect a voltage source set to
approximately 21V and start the Charger-Analyzer in AUTO
Discharge
•
Adjust for a Discharge CUT-OFF (Capacity Failure) at 20.0 volts.
•
NOTE: This step requires that the Overvoltage cut-off on the
MONITOR circuit board be previously calibrated.
9.2.3.3.
CLOCK-TIMER
•
No adjustments on this board.
•
Older versions of the Charger-Analyzer use two circuit boards
associated with timer functions: The Timer Board 9879903010 and
the Clock Display Board 9879903009.
•
Newer Superserseders use a single Clock-Timer Board
9879903109. In either case, there are no adjustments to perform.
9.2.3.4.
(Blank)
9.2.3.5.
CURRENT CONTROL (see fig 11).
NOTE: Use the hook at pin 14 as ground reference for voltage
measurements (test point E0).
9.2.3.5.1.
R29 - 10 VOLT ADJUSTMENT.
•
Static test (no battery or Calibrator).
•
Adjust for a reading of 10.000V ±0.003V at E7.
•
NOTE: Newer versions of this circuit board have a
fixed 10V reference (no adjustment). Verify that it
reads 10V ±0.005V.
9.2.3.5.2.
R28 - LOW CURRENT CALIBRATE.
•
Connect a battery and start the Charger-Analyzer in
Single Rate.
•
Adjust for a reading of 0.9 to 1.0 AMP at the current
digital panel meter, with the topping charge current
potentiometer set for 1 AMP (010).
9.2.3.5.3.
R25 - HIGH CURRENT CALIBRATE
•
Connect a battery and start the Charger-Analyzer in
Dual Rate.
•
Adjust for a reading of 25.0 AMPS at the current
digital panel meter, with the main current
potentiometer set for 25.0 AMPS (250).
Содержание Supercharger 60
Страница 7: ...Operator Manual Supercharger 60 R3 0 Page 7 of 62 Figure 1 Block Diagram ...
Страница 20: ...Operator Manual Supercharger 60 R3 0 Page 20 of 62 Figure 2 Front Panel ...
Страница 44: ...Operator Manual Supercharger 60 R3 0 Page 44 of 62 Figure 6 Meters Board Adjustments ...
Страница 52: ...Operator Manual Supercharger 60 R3 0 Page 52 of 62 Figure 11 Circuit Board Sequence ...
Страница 56: ...Operator Manual Supercharger 60 R3 0 Page 56 of 62 Figure 12 Measuring for a shorted transistor ...
Страница 57: ...Operator Manual Supercharger 60 R3 0 Page 57 of 62 Figure 13 Location of Current Limiters ...
Страница 58: ...Operator Manual Supercharger 60 R3 0 Page 58 of 62 Figure 14 Power Block Diagram ...