3.1.5.
MODES:
3.1.5.1.
Main and topping for Constant Current
3.1.5.2.
Constant Voltage
3.1.5.3.
Peak Voltage.
3.1.6.
TIMER:
3.1.6.1.
1 to 9 hours for MAIN charge time and 1 to 60 hours for TOTAL time.
3.1.6.2.
Time can also be programmed in minutes by selecting the FAST mode
in the TIMER SPEED selector switch (Front Panel).
3.1.6.3.
NOTE 1: Topping charge time equals the total charge time minus the
main charge time (TOTAL = MAIN + TOP).
3.1.6.4.
NOTE 2: Newer instruments may have a new version of the Timer
(Identified by an external Timer Speed Switch) that has a maximum of
79 (hours or minutes) in Total Time.
3.1.7.
OVERTEMP PROTECTION:
3.1.7.1.
Four thermistors on the TEMP-PLATE measure the battery
temperature.
3.1.7.2.
The charge is terminated when the surface temperature of the TEMP-
PLATE reaches 39
o
C (102
o
F).
3.1.8.
OVER/UNDER CURRENT PROTECTION:
3.1.8.1.
A Monitor circuit continuously compares the actual charge current
with the programmed value.
3.1.8.2.
Operation is terminated if they differ by more than 1 AMP.
3.1.9.
OVERVOLTAGE PROTECTION:
3.1.9.1.
Programmable, in accordance with the number of cells selected, at the
equivalent of 1.75 volts/cell (TOLERANCE: ±1%, ±0.1V).
3.1.9.2.
Absolute maximum internal limit set at 85 VOLTS.
3.1.9.3.
NOTE: Does not apply in the Float and Peak voltage modes. (Voltage
is controlled in those modes).
3.1.10.
REVERSE POLARITY PROTECTION:
3.1.10.1.
Operation of the unit is inhibited for reverse voltages greater than 0.5
VOLTS.
3.1.11.
FUSING:
3.1.11.1.
Aircraft type current limiter, ANL-60 (slow).
3.1.12.
AC LINE CURRENT:
Содержание Supercharger 60
Страница 7: ...Operator Manual Supercharger 60 R3 0 Page 7 of 62 Figure 1 Block Diagram ...
Страница 20: ...Operator Manual Supercharger 60 R3 0 Page 20 of 62 Figure 2 Front Panel ...
Страница 44: ...Operator Manual Supercharger 60 R3 0 Page 44 of 62 Figure 6 Meters Board Adjustments ...
Страница 52: ...Operator Manual Supercharger 60 R3 0 Page 52 of 62 Figure 11 Circuit Board Sequence ...
Страница 56: ...Operator Manual Supercharger 60 R3 0 Page 56 of 62 Figure 12 Measuring for a shorted transistor ...
Страница 57: ...Operator Manual Supercharger 60 R3 0 Page 57 of 62 Figure 13 Location of Current Limiters ...
Страница 58: ...Operator Manual Supercharger 60 R3 0 Page 58 of 62 Figure 14 Power Block Diagram ...