Cable requirements:

• Outdoor rated
• 

Conductor: 1 - 2.5 mm

2

 (14 - 17 AWG)

• Cores: 3
• 

Outer diameter: 6-15 mm (0.25 – 0.6”)

3.2 Connecting the Autonomic to power

1  

Connect the CEE Plug (exiting the Mains Power Adapter) to the CEE 

connector. The AVIX Autonomic is now powered and ready to be 
configured.

4. Configuration 

 CAUTION

• 

Do not drop. This product may malfunction if subjected to strong 
shocks or vibration.

• The AVIX Autonomic is an automated laser device intended for bird 

repelling purposes only.

• When using the AVIX Autonomic, always adhere to the safety 

precautions outlined in this document.

• To prevent injuries or damage as a result of entrapment, stay clear of 

the Motor Platform during operation. 

4.1 Power up

 CAUTION: Before using the AVIX Autonomic ensure that: 

• All bolts connecting the base of the Motor Platform to the supporting 

structure are tightly secured.

• The AVIX Autonomic is not allowed to wobble or tilt when 

operational. If stability is insufficient, improve supporting structure.

 

• The AVIX Autonomic should not be subjected to surface vibrations, 

as these can lead to a displacement of the laser projection over time.

• 

All power cables are properly connected.

• 

The emergency stop button is deactivated.

• The key is positioned inside the key lock switch and is switched to 

the ‘active’ position (turn in a clockwise direction).

 WARNING:

 

Do not stare into the laser beam during configuration. 

 CAUTION

 

After pressing the ( 

 ) button, the Motor Platform 

may start moving. Use the ( 

 ) button to switch the AVIX Autonomic 

ON/OFF. When powered, the AVIX Autonomic is automatically 
switched ON.

3. Assembly

1

   Carefully take all parts out of the AVIX Autonomic flight case.

2

   Position the Motor Platform on a flat and horizontal surface.

3

   Place the Payload on top of the Motor Platform by aligning the four 

holes on the top of the Motor Platform with the holes on the sides 

of the Payload. Make sure to position the Payload in the correct 
orientation, as shown in the Assembly overview on page 2. 

 CAUTION: Although the Payload may rest on the Motor Platform, 

it is not yet connected. Perform the next step carefully so the Payload 
will not drop.

4  

Use the 4 (four) screws to secure the Payload to the Motor Platform. 
Use the Hex Key to tighten the screws.

5  

Unscrew the connector protection cap on the back of the Rear Cap.

6  

Connect the Payload plug exiting on the side of the Motor Platform 

to the connector on the back of the Rear Cap. Make sure to tighten 
the screw connection properly to establish a watertight connection.

7  

Connect the plug exiting the base of the Motor Platform to the 

Power Switch Module.  Make sure to tighten the screw connection 
properly to establish a watertight connection.

8  

Connect the plug exiting the Mains Power Adapter to the remaining 

connector on the Power Switch Module. Make sure to tighten the 
screw connection properly to establish a watertight connection.

Secure the base of the Motor Platform to its supporting structure.

The Power Switch Module is a required module. The Autonomic will 

stay in the initialization phase if the Power Switch Module is not 

installed.

3.1 Preparing the mains power connection

 WARNING: Always make sure that all equipment is de-energized 

and disconnected from mains power before working on the mains 

power connection.

1  

 Connect the CEE Connector (mains power side) to the power cable 

(cable specifications are shown below). Use a flat blade screwdriver 
to open the connector and expose its terminals. Use a Philips screw 
driver to secure the cores to the terminals. Make sure the cores are 
stripped sufficiently and the screws are secured tightly to ensure 
proper conductivity. Close the connector again by combining its 
parts until it clicks into place.

2  

Power can be restored. Provide a voltage of 100 - 277V to the power 
cable. The mains power connection is ready for use.

The power cable is not provided with the AVIX Autonomic.

Содержание Mark II

Страница 1: ...1 AVIX Autonomic Mark II User manual Version 2 0 ...

Страница 2: ...1 User Manual AVIX Autonomic Mark II Version 2 0 F General overview Package contents 1x 1x 1x 1x 1x B C D E A M I J L K H G O N P ...

Страница 3: ...2 Assembly Figure 1 1 Figure 1 2 ...

Страница 4: ...3 User Manual AVIX Autonomic Mark II Version 2 0 Figure 2 4 Figure 2 2 Figure 2 1 Figure 2 5 Figure 2 3 ...

Страница 5: ...page 6 3 Assembly page 6 4 Configuration page 7 5 Maintenance page 9 6 Warranty page 9 7 Spare parts page 10 8 Accessories page 10 9 Troubleshooting page 11 English A CEE Plug B Mains Power Adapter C Power Switch Module D Motor Platform E Power socket F Payload G Rear Cap H Light Module inside Payload I Beam shutter lock J Laser aperture K Accessory slot L Beam shutter M LED status indicator N Pro...

Страница 6: ...er s failure willful or otherwise to operate the product in a correct and safe manner WARNING Carefully read all safety warnings and all instructions Retain all safety warnings and all instructions for future reference 1 Technical specifications AVIX Autonomic Mark II Laser class wavelength maximum output power divergence diameter at aperture NOHD MPE 3B 520 nm green continuous wave 500 mW 0 05 mr...

Страница 7: ...ht conditions These effects may have indirect safety implications if experienced by users during the performance of safety critical operations CAUTION The operator of the device must complete a laser safety training before using the AVIX Autonomic The AVIX Autonomic is to be used only by adults The AVIX Autonomic is to be used only for the purpose of repelling birds The Laser module Rear Cap Motor...

Страница 8: ...or Platform with the holes on the sides of the Payload Make sure to position the Payload in the correct orientation as shown in the Assembly overview on page 2 CAUTION Although the Payload may rest on the Motor Platform it is not yet connected Perform the next step carefully so the Payload will not drop 4 Use the 4 four screws to secure the Payload to the Motor Platform Use the Hex Key to tighten ...

Страница 9: ...fe to switch ON the laser WARNING In the next step the laser will be switched on Do not stare into the laser beam 10 2 Switch ON the laser by pressing the toggle button to the right top of the joystick area After enabling the laser the laser brightness can be adjusted at the top of the window and the joystick button turns green The laser brightness setting in this window only affects the brightnes...

Страница 10: ...tions The warranty is valid if the AVIX Autonomic is used in accordance with the instructions in this manual and for the purpose for which it was designed The warranty is valid when a valid receipt is presented that shows the date of purchase the name of the dealer and the product name 10 3 Move the laser to the desired position of the first waypoint and press the button Move the laser to the next...

Страница 11: ...ed disassembly Any repairs or attempts at repairs have been carried out by unauthorized persons Any defects have occurred as a result of using equipment other than provided by Bird Control Group including but not limited to using a different power adapter Any defects have occurred as a result of misuse or use in environments that are not prescribed The defect is a result of normal wear of replacea...

Страница 12: ...working because of the emergency stop on the Power Switch Module has been pressed After the emergency stop has been released the color of the AVIX Autonomic remains red Blinking red Error The AVIX Autonomic has encountered an error and user action is required If the autonomic was bursting it will automatically try to resolve this error every minute To check the error type please connect to the AVI...

Страница 13: ...12 ...

Страница 14: ......

Страница 15: ......

Страница 16: ...The Netherlands T 31 23 230 2030 E hello birdcontrolgroup com W www birdcontrolgroup com W www avix com North American Office 27350 SW 95th Ave Suite 3022 Wilsonville OR 97070 United States T 1 844 406 9280 toll free CONFIDENTIAL AVIX Autonomic is designed and manufactured by Published 01 05 2020 V2 0 ...

Отзывы: