background image

Required Installation Tools

Voltmeter
Wire Strippers
Electric Drill & Bits
Phillips Screw Driver
Convoluted Tubing *
Solder Gun *
Wire Crimpers
Shrink Tube or Electrical Tape

* Op tional

Important Information

1. Test all circuits with a voltmeter.
2. Make all wiring connections with butt connectors. DO NOT twist wires 

or use “scotch-lok” connectors.

3. Route RED, RED/WHITE and BLACK wires from the control unit

directly to the battery.

4. Keep extensions as short as possible. Use same gauge wires.
5. Before installing, discuss the placement of the LED indicator and valet

switch with the vehicle owner. DO NOT disconnect the battery cables.

6. Make all connections by removing the lug from the cable clamp

without detaching clamp.

7. Turn off dome light or remove dome light fuse to prevent battery drain.

This device complies with Part 15 of the FCC rules.  Any changes or
modifications made to the system without the express approval of Avital
Technologies, Inc. could void the user's authority to operate this
equipment.

3

Diablo

2

/AMX 68/AT-58 Installation Manual 3/31/99

Содержание AMX 68

Страница 1: ...1 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 Downloaded from http www guardianalarms net ...

Страница 2: ...el 2 Accessory Output 6 Parking Lights 6 Interior Light Trigger 7 Optional Interior Light Illumination Output 7 Starter Disable 7 Two Pulse Unlock 8 Door Lock Unlock Outputs 8 Hood Trunk Pin Switch 8 Siren 8 Power and Ground Connections 8 9 Door Lock Diagrams 9 11 Programming Alarm System Features 12 Programming Table for Alarm Features 12 Programming Your Remote Controls 13 Programming Table for ...

Страница 3: ...Keep extensions as short as possible Use same gauge wires 5 Before installing discuss the placement of the LED indicator and valet switch with the vehicle owner DO NOT disconnect the battery cables 6 Make all connections by removing the lug from the cable clamp without detaching clamp 7 Turn off dome light or remove dome light fuse to prevent battery drain This device complies with Part 15 of the ...

Страница 4: ...Wiring Diagram 4 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 ...

Страница 5: ...iren Output Tan Hood Trunk Input White Black Interior Light Illumination Output Requires Optional Relay Dark Blue Channel 2 Accessory Output White Door Trigger Input or Pink Ignition Switched 12 Volt Input Pre wired to Starter Disable Relay Blue White Door Lock Output Green White Door Unlock Output Starter Disable Relay Wire color Description 14 Ga Yellow Starter Disable Ignition Switch Side 14 Ga...

Страница 6: ...y to each connection point 3 Separate the RED RED WHITE BLACK VIOLET and TAN wires 4 Sleeve the wires with vinyl tubing or electrical tape and route them through an existing rubber grommet into the engine compartment 5 If an existing grommet is not available drill a hole and install a snap grommet Zone1 Impact Sensor The sensor must be firmly mounted on a solid metal surface inside the vehicle We ...

Страница 7: ... the ON CRANK and RUN position and 0 volts when the ignition key is in the OFF position 2 Connect the control unit PINK wire to the vehicle s ignition wire Channel 2 Accessory Output The DARK BLUE wire provides a 0 75 second ground output when the remote control button 2 is activated for 1 2 seconds If the remote control button 2 is continuously pressed the signal will stay at ground as long as th...

Страница 8: ...2 volt source 3 Connect relay terminal 30 to the vehicle door trigger wire s 4 If the vehicle door trigger is positive trigger connect relay terminal 87 to a fused 12 volt source 5 If the vehicle door trigger is negative trigger connect relay terminal 87 to ground Starter Disable Make sure the YELLOW relay wires are solidly connected The starter circuit may draw very high current We recommend that...

Страница 9: ...the alarm module TAN wire Siren 1 Choose a location in the engine compartment away from high heat engine components moving parts and direct exposure to water 2 Make sure the siren and siren wires cannot be seen or reached from below the vehicle 3 Mount the siren with the two self tapping screws to a solid metal surface 4 Connect the siren BLACK wire to the alarm module VIOLET wire 5 Connect the si...

Страница 10: ...y post 7 Connect the alarm BLACK wire to the battery negative post 8 Inspect all alarm wiring Make sure all wires are connected 9 Install the 5 amp fuse in the alarm module RED wire fuse assembly 10 Install the 20 amp fuse in the alarm module RED WHITE fuse assembly if the vehicle parking lights are positive 10 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 Negative Trigger Door Locks ...

Страница 11: ...11 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 ...

Страница 12: ...12 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 ...

Страница 13: ... Wait 3 seconds the siren will chirp once for 2 pulse or twice for 1 pulse 13 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 Programming Alarm System Features All programmable alarm features are accomplished by turning the ignition key on or starting the vehicle and flicking the valet switch on and off a preset number of times 1 Remove the alarm from valet Programming cannot be accessed while t...

Страница 14: ...n and off until you reach the number of chirps associated with your chosen feature NOTE Stop on the chirp 6 Follow the Secondary Action 7 Turn the ignition key off 8 Repeat steps 1 7 for any other feature you wish to program Programming Table for Remote Controls Feature Factory Setting of Chirps Secondary Action Arm Disarm Remote Panic Channel 1 9 Press any remote control button you choose to oper...

Страница 15: ...15 Diablo 2 AMX 68 AT 58 Installation Manual 3 31 99 Copyright 1998 Avital Technologies Inc 32 1241 98 ...

Отзывы: