background image

14 

 

Humidity limitation 

 

Atmospheric pressure limitation 

 

Caution 

 

Consult the instruction for use 

 

Disposal information: Should you wish to dispose of the 
article, do so in accordance with current regulations. Details 
are available from your local authority. WEEE 2012/19/EU 
Directives 

RoHS

 

 

This product fulfilling the requirements of the RoHS 
Directive 2011/65/EU. 

REACH

 

 

This product fulfilling the requirements of the REACH 
Directive EC 1907/2006 and its amendments, do not 
contain Substances of Very High Concern in concentration 
above the limit of 0.1 %. No substance(s) is/are present in 
the parts of the product above the concentration of 0.1 % 
weight by weight. 

 

Stand-by 

 

Device classification type BF 

Содержание TS12

Страница 1: ...mbH Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F No 78 Sec 1 Kwang Fu Rd San Chung Dist New Taipei City 24158 Taiwan Importer Distributor INSTRUCTION MANUAL Please read this instruction manual carefully before using your forehead thermometer ...

Страница 2: ...tion before Use 2 Product Identification 4 Description of LCD Display 5 Measuring Body Temperature on the Forehead 6 Memory Function 7 Cleaning and Disinfecting 7 Error Codes 9 Technical Specification 10 EMC Tables 11 Explanation of Symbols 13 ...

Страница 3: ...mometer takes temperatures in seconds by measuring the heat generated on the forehead Type of Use Reuse Multiple patient multiple use Intended User The Patient is an intended operator Patient selection criteria Handicapped persons and children are the exception of handicapped persons and children need assistance by another person to use the device ...

Страница 4: ...ning from outdoor 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Please use the thermometer solely for its intended purpose 12 There are no absolute body temperature standards Keep reliable records of your personal temperature to serve as a reference for judging a fever 13 Under any circumstances the temperatur...

Страница 5: ...3 19 If you would require any assistance during setting up using or maintaining please contact the manufacturer 20 Avoid using the device near an operating cell phone or microwave oven ...

Страница 6: ...4 Product Identification A Sensor Tip with Lens B Memory Button C Battery Cover D Power Measure Button E LCD Display ...

Страница 7: ...n of LCD Display 1 Memory symbol 2 Smiling face Measurement 38 C 100 4 F 3 Frowning face Measurement 38 C 100 4 F 4 Low battery Warning 5 Scan in Progress 6 Fahrenheit Scale 7 Celsius Scale 8 Degrees of Temperature ...

Страница 8: ... let you know the appliance is ready and followed by last temperature reading 3 When the beep sounds to let you know the appliance is ready press the Power Measure button and maintain pressure 4 Place the probe on your temple Slide the probe across your forehead to the other temple and then release pressure on button to stop temperature taking You ll hear a beep and your temperature will come up o...

Страница 9: ...r home use device disinfection 75 Ethanol Isopropyl alcohol available in the pharmacy can be used Probe and Tip Clean the probe and tip with an75 Ethanol or Isopropyl alcohol before and after each measurement Thermometer Use a soft dry cloth to clean thermometer body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens or the display Do n...

Страница 10: ...erly dispose of the batteries away from small children and heat Batteries must be disposed of in accordance with local environmental and institutional policies Do not use rechargeable batteries 1 Open the battery case by sliding off the cover on the back of the unit 2 Remove used battery 3 Replace with 1 x 3V CR2032 battery in designated area The larger part of the battery should be facing up You ...

Страница 11: ...an 43 C 109 4 F Operate the thermometer only between the specified temperature ranges If necessary clean the sensor tip In the event of a repeated error message contact your retailer or Customer Services The temperature measured is lower than 34 C 93 2 F The operating temperature is not in the range 15 C 40 C 59 F 104 F Operate the thermometer only between the specified temperature ranges ...

Страница 12: ...sure 700 1060 hPa Storage Transportation environment 25 C 55 C 13 F 131 F with relative humidity up to 95 non condensing Atmospheric Pressure 700 1060 hPa Display resolution 0 1 C Power supply 1 x 3V CR2032 Auto switch off in 60 seconds without operation Memory 10 sets Weight approx 45g with batteries Dimensions approx 34 x 117 x 29 mm W x H x D Typical Service Life 3 years Battery Shelf Life 5 ye...

Страница 13: ...onsidered and applied The equipment is suitable for use in the mentioned environments when directly connected to the Public Mains Network b The test is not applicable in this environment unless the ME EQUIPMENT and ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the scope of the Basic EMC standard Guidance and manufacturer s declaration Electrom...

Страница 14: ...ncy magnetic fields IEC 61000 4 8 30 A m c 50 Hz or 60 Hz a The equipment is suitable for use in Home Health Environments and Professional Health Care Environments limited to patient rooms and respiratory treatment facilities in hospital or clinics The more restrictive IMMUNITY acceptance limits have been considered and applied b Before modulation is applied c This test level assumes a minimum dis...

Страница 15: ...tified Body This denotes the compliance of European Medical Device Directive 93 42 EEC Medical Device Manufacturer Authorized representative in the European Community Date of manufacture YYYY MM DD or YYYY MM Batch code YYMMWWWW Serial number YYMWWWXXXXX Keep dry Temperature limit ...

Страница 16: ...hority WEEE 2012 19 EU Directives RoHS This product fulfilling the requirements of the RoHS Directive 2011 65 EU REACH This product fulfilling the requirements of the REACH Directive EC 1907 2006 and its amendments do not contain Substances of Very High Concern in concentration above the limit of 0 1 No substance s is are present in the parts of the product above the concentration of 0 1 weight by...

Страница 17: ...er and against vertically falling water drops when enclosure tiled up to 15 The empty completely flat batteries must be disposed of through specially designated collection boxes recycling points or electronics retailers You are legally required to dispose of the batteries Importer Distributor Model Number Country of Manufacturer Unique Device Identifier TS12P 22105AV 2022 04 22 ...

Отзывы: