ENVIRONMENT CONDITIONS

This device is designed to be used indoors (0

o

C to 45

o

C with relative humidity between 

20% to 80% not condensing). Sudden changes of temperature and humidity should be 

avoided.

CLEANING AND MAINTENANCE

Use a soft dry cloth. Do not use solvent or abrasive products.

SAFETY

Please read these safety instructions before starting the device.

 

+

Do not expose this device to liquids or excessive humidity. The DCP is an indoor device and 
is not waterproof.

 

+

Do not expose the device to fire.

 

+

Do not try to modify the device. 

 

+

Do not use the device in potentially hazardous areas or where there is risk of explosion.

The DCP emits low levels of radio frequency when in operation.

BATTERY

The DCP includes a NiCd 12 V/600 mAh battery that allows it to keep functioning in the 

event of a mains power failure.

This battery should be replaced every 4 years. Only install batteries authorized by Avire, 

and only allow qualified personnel to replace the battery.

This battery should be properly recycled and not disposed of with unsorted household 

waste. Please take all neccessary precautions when changing the battery.

DISPOSAL

The device complies with regulations 2002/95/CE and 2003/108/CE regarding 

the use and disposal of hazardous substances in electric appliances.

Do not dispose of this device with unsorted household waste. Disposing 

of the device in an unauthorised way could result in a fine in line with local 

regulations.

ENVIRONMENTAL REGULATIONS

RoHS - Avire certifies that its production process complies with the 2011/65/EU 

European Directive of 03 January 2013 regarding the restriction of use of hazardous 

substances in electric and electronic appliances.

INSTALLATION

The equipment is intended for installation in restricted areas by qualified personnel. 

GENERAL NOTE

Any wiring or plug used together with the equipment must be certified in line with 

relevant product standards. The wiring insulation must comply with the applicable IEC 

60332 or IEC 60695/11/21 standards. 

This device must be installed by qualified personnel and always in a restricted area 

where only such personnel have access.

Содержание AC-3CM10-620-F-20-000

Страница 1: ...and our online monitoring platform the Avire Hub The product is installed as a stand alone device and doesn t require connection to the controller panel Dual SIM card DCP version only A dual SIM card...

Страница 2: ...use the signal scanner function Turn SW1 dipswitch 1 to ON check dipswitch 4 is also ON Please refer to pages 13 and 14 for the full picture and connector information 1 Open the DCP with a PZ1 screwd...

Страница 3: ...y time by referring to the LED Indicators page 15 7 With the power supply turned off connect power 230VAC to J6 using the 3pin connector supplied with the unit Note The signal scanner will indicate th...

Страница 4: ...Battery is OK SIM LED is green or amber Device is connected to the network Coverage LED is green or amber Good coverage SLIC LED is green Device is in standby J6 11 To fix the device in position drill...

Страница 5: ...nter SIM card PIN parameter xxxx is the SIM PIN code given by the service provider for SIM0 Dual SIM card version Enter DCP configuration mode wait for DCP voice command Enter SIM card PIN parameter x...

Страница 6: ...M1 Network Digit 2 4 Network Country 0 default default 1 AvireSim 2 Telstra AUS 3 Optus AUS 4 Vodafone AUS 5 Spark NZ 6 2 degrees NZ 7 Vodafone NZ 8 9 Digit 3 0 1 2 3 Type Transparent Gateway Avire Hu...

Страница 7: ...ssword Vodafone AUS live vodafone com blank blank Telstra AUS telstra iph blank blank Spark NZ internet blank blank Other APN settings are available on the web and can be easily found online If an APN...

Страница 8: ...It is also possible to retrieve the CCID number by sending a SMS command to a SIM card telephone number the command needs to be separated by a comma as shown below Pin1234 P005 You will receive a tex...

Страница 9: ...ub is http avirehub avire global com To view installation tutorial videos please go to the Help section of the Avire Hub Click on Installations in the menu on the side and then on Buildings Inside of...

Страница 10: ...up names to easily identify installations Once all information is entered click Next In the new page you should be able to see Groups and Elevators Click on Add Gateway under Gateway tab and select DC...

Страница 11: ...should now be accessible Click on the Access button Please click on the Read Parameters button On the right hand side of the page you will see a window with time date and the word Connecting shown in...

Страница 12: ...number CMD Description Default value P005 CCID Unique Identifier of the Sim Card 19 digits P020 DCP Background Call Mode P020 00 Transparent Protocol P020 06 CAN Protocol P020 21 P100 Protocol 21 Aut...

Страница 13: ...h the kit to the J2 connector Only antennas approved by Avire should be used in the installation otherwise the device might not function properly and may be damaged J3 Battery Pin Function Signal 1 12...

Страница 14: ...2 TX Out 7 RTS Out 3 RX In 8 CTS In 5 Ground Ground RS 232 Pin Signal Pin Signal 2 T T RS422 7 T T RS422 3 R R RS422 8 R R RS422 5 Ground Ground RS 422 J11 Digital Input Output Pin Function Signal 1 A...

Страница 15: ...er Operation AC Proper Operation BAT Restarting System BATTERY OFF ON FLASHING Green Amber Red Orange Red OK Charging Low DAU battery failure Error SIM OFF ON Flashing Green Amber Red Green Amber Red...

Страница 16: ...System Architectures DCP Triphony Unit Universal Power Display Digital Audio Unit COP Induction Loop CAN Bus Splitter PIT Phone Lift car system architecture with DCP DAU TOC Triphony Unit Inductive Lo...

Страница 17: ...Units Two lift cars with DCP UPS CANBus Splitter TOC Triphony Unit DAU PIT Phone Four lift cars with DCP UPS CANBus Splitters DAU Triphony Units TOC PIT Phones There is a maximum of two CANBus Splitte...

Страница 18: ...et SW1 dipswitch 4 to ON It is recommended to use shielded twisted pair cables If connecting 2 devices to the DCP e g 1 DAU and 1 PIT unit set SW1 dipswitch 4 to OFF There are no standard wiring colou...

Страница 19: ...onnecting a Memcom use the analogue phone line connection from J1A or J9 Please refer to the Memcom installation guide for full set up of the Memcom J9 GSM phone line OUT N L Connections on DCP J9 GSM...

Страница 20: ...tall batteries authorized by Avire and only allow qualified personnel to replace the battery This battery should be properly recycled and not disposed of with unsorted household waste Please take all...

Отзывы: