background image

12

ADDITIONAL INFORMATION FOR PROGRAMMING THE DCP

SMS COMMANDS

 

+

All DCP parameters can be remotely configured via SMS sent to the SIM card’s number. 

 

+

Each SMS message should begin with ‘Pin1234’ which is the access code to read or make any changes to the 
configuration of the DCP.

 

+

You can modify or check several parameters in each SMS by separating them with commas ","

To send parameter information:

Text

Description

Pin1234, Pzzz xxx 

(send)

• 

Pin1234 is default PIN code for DCP

• 

Pzzz is the programming command

• 

xxx is the parameter

To read parameter information:

Text

Description

PinXXXX, Pzzz? 

(send)

• 

Pin1234 is default PIN code for DCP

• 

Pzzz is the programming command

• 

“?” is to request a parameter read

Note: Use a question mark ‘?’ when you are reading parameters.
Examples:

1. 

To program telephone number 1 in the DCP when connected to a DAU 

E.g: Pin1234, P031 0123456789 (send, text message will come back with P031=0123456789)

2. 

To retrieve telephone number 1 in the DCP when connected to a DAU

E.g: Pin1234, P031? (send, text message will come back with P031= or with the programmed number)

CMD

Description

Default value

P005

CCID- Unique Identifier of the Sim Card

(19 digits)

P020

DCP Background Call Mode 

P020=00 -> Transparent Protocol

P020=06 -> CAN Protocol

P020=21 -> P100 Protocol

21 (Autodialler’s need to make 

Background calls in P100 

Protocol) 

P064

Background Call Periodicity (in Minutes)

4320 (3 days)

P030

Maintenance Alarm Number

(Blank)

P031

Alarm Number 1

(Blank – Insert your alarm 

number here)

P032

Alarm Number 2

(Blank)

P033

Alarm Number 3

(Blank)

P034

Alarm Number 4

(Blank)

P035

Background Number (not used with DAU)

3308084431 (must match 

Background Number in 

Autodialler, without prefixes)

P008

Enable Guidance Message *

0 (disabled)

P085

Language

4 (English)

P091

Super settings set up

000

P003

DCP information (software version, type of DCP)

As per package

P051

Dual SIM settings

0

Important Note: The default PIN code for DCP is always 1234.

 

Parameter P051 - Dual SIM card version:

0

SIM0 acting as a primary SIM card. In case of failure of primary SIM, it will switch to SIM1.

1

SIM1 acting as a primary SIM card. In case of failure of primary SIM, it will switch to SIM0.

2

SIM0 - Voice SIM, SIM1 - Data SIM. SIM1 is attahed to network, listening to any incoming calls, once an alarm call 

is active, the DCP will switch to SIM0 and stay active till the end of alarm.

Содержание AC-3CM10-620-F-20-000

Страница 1: ...and our online monitoring platform the Avire Hub The product is installed as a stand alone device and doesn t require connection to the controller panel Dual SIM card DCP version only A dual SIM card...

Страница 2: ...use the signal scanner function Turn SW1 dipswitch 1 to ON check dipswitch 4 is also ON Please refer to pages 13 and 14 for the full picture and connector information 1 Open the DCP with a PZ1 screwd...

Страница 3: ...y time by referring to the LED Indicators page 15 7 With the power supply turned off connect power 230VAC to J6 using the 3pin connector supplied with the unit Note The signal scanner will indicate th...

Страница 4: ...Battery is OK SIM LED is green or amber Device is connected to the network Coverage LED is green or amber Good coverage SLIC LED is green Device is in standby J6 11 To fix the device in position drill...

Страница 5: ...nter SIM card PIN parameter xxxx is the SIM PIN code given by the service provider for SIM0 Dual SIM card version Enter DCP configuration mode wait for DCP voice command Enter SIM card PIN parameter x...

Страница 6: ...M1 Network Digit 2 4 Network Country 0 default default 1 AvireSim 2 Telstra AUS 3 Optus AUS 4 Vodafone AUS 5 Spark NZ 6 2 degrees NZ 7 Vodafone NZ 8 9 Digit 3 0 1 2 3 Type Transparent Gateway Avire Hu...

Страница 7: ...ssword Vodafone AUS live vodafone com blank blank Telstra AUS telstra iph blank blank Spark NZ internet blank blank Other APN settings are available on the web and can be easily found online If an APN...

Страница 8: ...It is also possible to retrieve the CCID number by sending a SMS command to a SIM card telephone number the command needs to be separated by a comma as shown below Pin1234 P005 You will receive a tex...

Страница 9: ...ub is http avirehub avire global com To view installation tutorial videos please go to the Help section of the Avire Hub Click on Installations in the menu on the side and then on Buildings Inside of...

Страница 10: ...up names to easily identify installations Once all information is entered click Next In the new page you should be able to see Groups and Elevators Click on Add Gateway under Gateway tab and select DC...

Страница 11: ...should now be accessible Click on the Access button Please click on the Read Parameters button On the right hand side of the page you will see a window with time date and the word Connecting shown in...

Страница 12: ...number CMD Description Default value P005 CCID Unique Identifier of the Sim Card 19 digits P020 DCP Background Call Mode P020 00 Transparent Protocol P020 06 CAN Protocol P020 21 P100 Protocol 21 Aut...

Страница 13: ...h the kit to the J2 connector Only antennas approved by Avire should be used in the installation otherwise the device might not function properly and may be damaged J3 Battery Pin Function Signal 1 12...

Страница 14: ...2 TX Out 7 RTS Out 3 RX In 8 CTS In 5 Ground Ground RS 232 Pin Signal Pin Signal 2 T T RS422 7 T T RS422 3 R R RS422 8 R R RS422 5 Ground Ground RS 422 J11 Digital Input Output Pin Function Signal 1 A...

Страница 15: ...er Operation AC Proper Operation BAT Restarting System BATTERY OFF ON FLASHING Green Amber Red Orange Red OK Charging Low DAU battery failure Error SIM OFF ON Flashing Green Amber Red Green Amber Red...

Страница 16: ...System Architectures DCP Triphony Unit Universal Power Display Digital Audio Unit COP Induction Loop CAN Bus Splitter PIT Phone Lift car system architecture with DCP DAU TOC Triphony Unit Inductive Lo...

Страница 17: ...Units Two lift cars with DCP UPS CANBus Splitter TOC Triphony Unit DAU PIT Phone Four lift cars with DCP UPS CANBus Splitters DAU Triphony Units TOC PIT Phones There is a maximum of two CANBus Splitte...

Страница 18: ...et SW1 dipswitch 4 to ON It is recommended to use shielded twisted pair cables If connecting 2 devices to the DCP e g 1 DAU and 1 PIT unit set SW1 dipswitch 4 to OFF There are no standard wiring colou...

Страница 19: ...onnecting a Memcom use the analogue phone line connection from J1A or J9 Please refer to the Memcom installation guide for full set up of the Memcom J9 GSM phone line OUT N L Connections on DCP J9 GSM...

Страница 20: ...tall batteries authorized by Avire and only allow qualified personnel to replace the battery This battery should be properly recycled and not disposed of with unsorted household waste Please take all...

Отзывы: