AVIRE AC-2CT18-100-0-2L-000 Скачать руководство пользователя страница 14

14

7. 

External Pictogram (LED’s) Voltage Selection

This switch allows you to choose either 12V or 24V output for 
the external pictogram LED’s (default 12V). 

Connector Details 

Label

Connector

Description

1

Antenna

External antenna – Only use antennas authorised by Avire, otherwise the device might not 
work.

2

SIM card

Insert Avire or Non-Avire SIM card here

3

Battery

Internal battery*

4

Prog. DCP

Required for debugging (only for Avire Technical support)

5

DCP configuration

See DCP configurations

6

Serial Connector

RS-232 or 422/485 Serial Connector

7

SLIC

Phone line 

8

Power

External power supply

9

Fuse

Exchangeable fuse

10

LPBus

Low Power Bus which connects to external audio units and other LPBus devices

11

DAU outputs
(siren)

Type N outputs, open collector, 
configurable by parameters. The maximum 
switching voltage is 30VDC and the 
maximum current for each output is 150mA. 

12

6 Car alarm

Cabin alarm button **

5 Vout

Common output 

4 Filter

Alarm filter **

3 Top/Bot alarm

External alarm push to generate call

2 Intercom

Intercom call to machine room handset

1 Vout

Common output

Pin

Function

Signal

1

L1

Tip

2

L2

Ring

Pin

Function

Signal

1

L

Live

2

N

Neutral

Содержание AC-2CT18-100-0-2L-000

Страница 1: ...mmunication with the machine room through the Intercom function IN THE BOX DCP Wave Antenna P 5 H 2V connector Phone Connector x1 P 10 H 2V connector Power Connector x1 P 3 5 H 6V connector Input conn...

Страница 2: ...LED lights to turn on Check the SIM LED to make sure it is green or amber If it is flashing red check its been inserted correctly and then unlock the SIM using instructions in how to unlock the SIM Ca...

Страница 3: ...ided inside the box You can check the status of the power supply battery connection coverage or Phone line at any time by referring to the LED indicators Run LED flashes in green Power supply is OK BA...

Страница 4: ...g site Basic Programming DCP DAU 1 Via SMS Pin1234 P031 customer emergency alarm number Confirmation SMS will show on mobile phone Mk775 1234567890 number P031 programmed alarm number shown 2 Using a...

Страница 5: ...version Enter DCP configuration mode wait for DCP voice command Enter SIM card PIN parameter xxxx is the SIM PIN code given by the service provider for SIM0 Dual SIM card version Enter DCP configurat...

Страница 6: ...ecify any use case or country Digit 2 4 1 2 3 4 5 6 Country Spain Portugal Italy UK Germany France 0 default default default default default default 1 AvireSim AvireSim AvireSim AvireSim AvireSim Avir...

Страница 7: ...ank blank Orange France Orange fr orange orange Other APN settings are available on the web and can be easily found online If an APN is incorrect for the provider or is not set up correctly the DCP wi...

Страница 8: ...DS It is also possible to retrieve the CCID number by sending a SMS command to a SIM card telephone number the command needs to be separated by a comma as shown below Pin1234 P005 You will receive a t...

Страница 9: ...Configurations Dipswitch SW1 DAU Configurations Dipswitch 17 Additional Information for Programming the DCP ADDITIONAL INFORMATION FOR PROGRAMMING THE DCP All DCP parameters can be remotely configured...

Страница 10: ...Polarity change to N C N C Parameter P051 Dual SIM card version 0 SIM0 acting as a primary SIM card In case of failure of primary SIM it will switch to SIM1 1 SIM1 acting as a primary SIM card In case...

Страница 11: ...handset ii Lift the phone off the handset and enter the commands to be configured using the dial pad The parameters shall be entered as follows with a synthesized audio voice played back as a respons...

Страница 12: ...0 Off 1 On 1 PC15 Automatic End of Alarm EOA 0 Off 1 On 0 PC16 Privacy Mode 0 off 1 On 1 PC21 LED Mode 0 Full 1 EN81 28 1 PC22 Alarm call retry attempts 5 PC23 Maintenance call retry attempts 3 PC24 E...

Страница 13: ...utton has voltage Top Bot Alarm External alarm push to generate call Intercom Call Provides intercom functionality to call to the DCP handset usually located in the machine room Alarm Filter Can filte...

Страница 14: ...onfigurations 6 Serial Connector RS 232 or 422 485 Serial Connector 7 SLIC Phone line 8 Power External power supply 9 Fuse Exchangeable fuse 10 LPBus Low Power Bus which connects to external audio uni...

Страница 15: ...utton has voltage Internal microphone connected at factory only reconnect if accidently disconnected Notes End of Alarm EOA This indicates that the emergency lift trapping rescue is complete and the a...

Страница 16: ...n with all connected audio modules and the external receiver The local intercom connection will automatically be disabled when the external call is hung up Once external communication is established t...

Страница 17: ...om 52dB m to 109dB m Please remember to switch SW1 1 to OFF to return to normal operations DCP LED Indicators The DCP has five indicator LEDs that constant report the device status The indicators will...

Страница 18: ...GPRS not available Out of Service Initialising Ongoing Data Transmission Ongoing voice call Sim error or missing pin Amber Red Missing PUK SLIC OFF ON FLASHING Green Amber Red Green RS 232 local conf...

Страница 19: ...ub is https avirehub avire global com To view installation tutorial videos please go to the Help section of the Avire Hub Click on Installations in the menu on the side and then on Buildings Inside of...

Страница 20: ...tively You can also edit the group names to easily identify installations Once all information is entered click Next In the new page you should be able to see Groups and Elevators Click on Add Gateway...

Страница 21: ...should now be accessible Click on the Access button Please click on the Read Parameters button On the right hand side of the page you will see a window with time date and the word Connecting shown in...

Страница 22: ...zed by Avire and only allow qualified personnel to replace the battery This battery should be properly recycled and not disposed of with unsorted household waste Please take all necessary precautions...

Страница 23: ...Fig 7 www avire global com Avire UK t 44 0 1628 540100 e sales uk avire global com...

Отзывы: