12
The table below indicates all the parameters which can be set on the DAU (SMS
Commands):
Additional Information for Programming the DAU
CMD
Description
Default Value
PC07
Direct the first alarm call to DCP telephone (0-No,
1-Yes)
0
PC08
Alarm call bypass filter time (0-10s)
10
PC09
Reset to Factory Default
N/A
PC10
Reboot Digital Audio Unit
N/A
PC11
Alarm Button countdown timer (s)
3
PC12
Alarm filter input (0-Off, 1-On)
0
PC13
Cancel alarm by pressing alarm button (0-Off, 1-On)
0
PC14
Wait for Alarm acknowledgement (0-Off, 1-On) *
1
PC15
Automatic End of Alarm EOA (0-Off, 1-On)
0
PC16
Privacy Mode ** (0-off, 1-On)
1
PC21
LED Mode (0-Full, 1-EN81-28)
1
PC22
Alarm call retry attempts
5
PC23
Maintenance call retry attempts
3
PC24
Elevator Car microphone volume
5
PC25
Elevator car speaker volume
5
PC26
Elevator car announcement volume
5
PC28
Language ***
(1 – Spanish, 2 – Portuguese, 3 – Italian, 4 – English,
5 – German, 6 – French)
100000
PC29
Time between alarm calls (s)
0
C = number of the car you need to check / configure
*If the Alarm Acknowledgement is on, the operator must press “0” to acknowledge the alarm
**The microphone inside the car is disconnected if there’s no emergency alarm call
***The DAU can use up to six languages, each digit being its sequence order