AVIRE AC-2CT18-100-0-2L-000 Скачать руководство пользователя страница 1

1

DCP WAVE 

Digital Communication Platform with integrated Digital Audio Unit

Installation Guide

Ref No: MU-89112AV101V01 GB

Product Part Number:
4G: AC-4CT18-100-0-4L-000
2G: AC-2CT18-100-0-2L-000

The DCP WAVE combines the Digital Communication Platform (DCP) with the Top-of-
Car Digital Audio Unit (TOC DAU) into one device and provides 2-way communication 
from inside the car to the top of car. The unit is mounted on the top of lift car and it 
does not require connection to the machine room. 

You have the possibility to use a microphone in the cabin and to control external 12V 
or 24V pictograms. It also allows audio communication with the machine room through 
the “Intercom” function.

IN THE BOX

 

+

DCP Wave

 

+

Antenna

 

+

P-5 H-2V connector (Phone 
Connector) (x1)

 

+

P-10 H-2V connector (Power 
Connector) (x1)

 

+

 P-3.5 H-6V connector (Input 
connector) (x1) Ext. Siren output cable 
wire loom (1m with 3 outputs)

 

+

Grey clamp (x2)

 

+

 Screws (x4)

 

+

Box fixing Screws (x2)

 

+

Installation Guide

NOT INCLUDED

 

+

Screwdriver

 

+

SIM Card (Avire SIM can be purchased 

through sales)

SPECIFICATION: 2G & 4G VERSIONS

DCP WAVE

Input

4G: 100 – 240 VAC mains power

2G: 220 – 240 VAC mains power

Consumption

max. 10 VA

Internal Battery

12V, 600 mAh, 9hr

Connections

RS232 or RS422/485; CANbus, LPBus 

Operating Temp

-10ºC to +65ºC

Dimensions

320x116x77mm

Network

2G or 4G available

Note: Before installation pease ensure there is good signal coverage using the inbuilt 
signal strength scanner. 

Typical System Architecture

Содержание AC-2CT18-100-0-2L-000

Страница 1: ...mmunication with the machine room through the Intercom function IN THE BOX DCP Wave Antenna P 5 H 2V connector Phone Connector x1 P 10 H 2V connector Power Connector x1 P 3 5 H 6V connector Input conn...

Страница 2: ...LED lights to turn on Check the SIM LED to make sure it is green or amber If it is flashing red check its been inserted correctly and then unlock the SIM using instructions in how to unlock the SIM Ca...

Страница 3: ...ided inside the box You can check the status of the power supply battery connection coverage or Phone line at any time by referring to the LED indicators Run LED flashes in green Power supply is OK BA...

Страница 4: ...g site Basic Programming DCP DAU 1 Via SMS Pin1234 P031 customer emergency alarm number Confirmation SMS will show on mobile phone Mk775 1234567890 number P031 programmed alarm number shown 2 Using a...

Страница 5: ...version Enter DCP configuration mode wait for DCP voice command Enter SIM card PIN parameter xxxx is the SIM PIN code given by the service provider for SIM0 Dual SIM card version Enter DCP configurat...

Страница 6: ...ecify any use case or country Digit 2 4 1 2 3 4 5 6 Country Spain Portugal Italy UK Germany France 0 default default default default default default 1 AvireSim AvireSim AvireSim AvireSim AvireSim Avir...

Страница 7: ...ank blank Orange France Orange fr orange orange Other APN settings are available on the web and can be easily found online If an APN is incorrect for the provider or is not set up correctly the DCP wi...

Страница 8: ...DS It is also possible to retrieve the CCID number by sending a SMS command to a SIM card telephone number the command needs to be separated by a comma as shown below Pin1234 P005 You will receive a t...

Страница 9: ...Configurations Dipswitch SW1 DAU Configurations Dipswitch 17 Additional Information for Programming the DCP ADDITIONAL INFORMATION FOR PROGRAMMING THE DCP All DCP parameters can be remotely configured...

Страница 10: ...Polarity change to N C N C Parameter P051 Dual SIM card version 0 SIM0 acting as a primary SIM card In case of failure of primary SIM it will switch to SIM1 1 SIM1 acting as a primary SIM card In case...

Страница 11: ...handset ii Lift the phone off the handset and enter the commands to be configured using the dial pad The parameters shall be entered as follows with a synthesized audio voice played back as a respons...

Страница 12: ...0 Off 1 On 1 PC15 Automatic End of Alarm EOA 0 Off 1 On 0 PC16 Privacy Mode 0 off 1 On 1 PC21 LED Mode 0 Full 1 EN81 28 1 PC22 Alarm call retry attempts 5 PC23 Maintenance call retry attempts 3 PC24 E...

Страница 13: ...utton has voltage Top Bot Alarm External alarm push to generate call Intercom Call Provides intercom functionality to call to the DCP handset usually located in the machine room Alarm Filter Can filte...

Страница 14: ...onfigurations 6 Serial Connector RS 232 or 422 485 Serial Connector 7 SLIC Phone line 8 Power External power supply 9 Fuse Exchangeable fuse 10 LPBus Low Power Bus which connects to external audio uni...

Страница 15: ...utton has voltage Internal microphone connected at factory only reconnect if accidently disconnected Notes End of Alarm EOA This indicates that the emergency lift trapping rescue is complete and the a...

Страница 16: ...n with all connected audio modules and the external receiver The local intercom connection will automatically be disabled when the external call is hung up Once external communication is established t...

Страница 17: ...om 52dB m to 109dB m Please remember to switch SW1 1 to OFF to return to normal operations DCP LED Indicators The DCP has five indicator LEDs that constant report the device status The indicators will...

Страница 18: ...GPRS not available Out of Service Initialising Ongoing Data Transmission Ongoing voice call Sim error or missing pin Amber Red Missing PUK SLIC OFF ON FLASHING Green Amber Red Green RS 232 local conf...

Страница 19: ...ub is https avirehub avire global com To view installation tutorial videos please go to the Help section of the Avire Hub Click on Installations in the menu on the side and then on Buildings Inside of...

Страница 20: ...tively You can also edit the group names to easily identify installations Once all information is entered click Next In the new page you should be able to see Groups and Elevators Click on Add Gateway...

Страница 21: ...should now be accessible Click on the Access button Please click on the Read Parameters button On the right hand side of the page you will see a window with time date and the word Connecting shown in...

Страница 22: ...zed by Avire and only allow qualified personnel to replace the battery This battery should be properly recycled and not disposed of with unsorted household waste Please take all necessary precautions...

Страница 23: ...Fig 7 www avire global com Avire UK t 44 0 1628 540100 e sales uk avire global com...

Отзывы: