28
Part 4Custom control command
Command
Function
Command packed
Comments
CAM_Power
On
8x 02 16 16 16 65 FF
Custom Power ON/OFF
OFF(Standby)
8x 02 16 16 16 56 FF
TCL_Power
TCL Standby
8x 01 02 75 75 01 04 FF
Forwarding
AD DA 02 B0 01 04 AF FA
TCL Wakeup
8x 01 02 75 75 00 03 FF
Forwarding
AD DA 02 B0 00 03 AF FA
Part 5 Customize the query command
Command
Command packed
Inquiry Packet
Comments
CAM_StatusInq
8x 02 20 01 01 FF
y0 50 0p 00 0q rs 0t 0u
FF
p:Error code
q:License
rs:Video format
t:Flip mode
u:Running status
Note:
The [x] in the above table is the camera address, [y] = [x + 8].