![Aviosys IP Power 9858 MT Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/aviosys/ip-power-9858-mt/ip-power-9858-mt_user-manual_3031919009.webp)
- 9 -
Rear View
⚫
9858MT-S :
⚫
9858MT-T :
Interface from Left to right :
4 outlets
Connect up to 4 individual outlets to be controlled by the 9858MT. Ports
sequence as 4 / 3 / 2 / 1 .
⚫
9858MT-S : IEC320 socket , 10A / 240VAC
⚫
9858MT-T : NEMA socket , 15A / 100VAC
Power Input &
Fuse socket
In this socket, there are one power input and one fuse socket .
⚫
Power input : 100-240VAC. 10A 240VAC or 15A 100VAC
⚫
Fuse
: To prevent electrical surges from damaging the unit. The
9858MT comes with two fuses in the socket ,one is usage and
another one is a spare for replacement .
TYPE
:
10A 250V ( 9858MT-S ) or 15A 250V ( 9858MT-T)
Power Switch
The Power switch turns on the input power. For device power reboot by
one click. It will take 70 seconds for the system boot up.
⚫
Fuse replacement
1.) The fuse is located between the power switch and the power input plugs.
2.) Carefully remove the fuse holder with a flat screwdriver.
3.) The fuse can be purchased from electronic shops. Specification : 10A 250VAC