![Aviosys IP Power 9223K-A Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/aviosys/ip-power-9223k-a/ip-power-9223k-a_user-manual_3031900011.webp)
- 11-
Ref#9223K05260001
Note:
Please remember that you use normally open or normally closed the output control will either create a open
circuit or a closed circuit.
Device Status
Control Status
Circuit
Normally Closed
On
Open
Normally Open
On
Closed
Connecting devices to the 9223K-A
Warning:
This part of the procedure can be very dangerous. Please follow instructions carefully or consult
an electrician or someone who is experienced in the field to assist in the part of the procedure. Aviosys is
not responsible for any damages to the device or harm caused by from misuse, incorrect installation, and (or)
dangerous environment.
When connecting the device it is crucial not to have the power of the 9223K-A connected.
1.) First connect the cables to the 9223K-A. Make sure that you have stripped enough of the cable so
that the contacts can fit into the 9223K-A.
a. During this part you will need to decide whether each relay will start normally open or
normally closed. Once you have decided, carefully unscrew the inputs and place the
contacts into the input area and screw on tightly.
2.) Plug in the network cable RJ45 into the 9223K-A
3.) After correctly installing steps 1 and 2 for the very last step plug in the power cable that came with
9223K-A.