Command format :
IPPOWERCTRL:TAG=Test;POWER1=OFF;POWER2=OFF;POWER3=OFF;POWER4=OFF
;POWER5=ON; POWER6=ON; POWER7=ON; POWER8=ON
There are 2 section of the command
1. IPPOWERCTRL:TAG=Test
This is command part. Beside the tag message part ( like Test on above example) user can
change in setting section , the other command must be
CAPITAL
and are fixed content .
2. ;POWER1=OFF;POWER2=OFF;POWER3=OFF;POWER4=OFF
;POWER5=ON; POWER6=ON; POWER7=ON; POWER8=ON
This is to set the outlet number ( POWER1= ) and action ( ON/OFF) , user can only control 1~8
port ON/OFF by email. Please Each outlet command
EX: Put “ 148ON” in tag section and place the command as following : ( at subject or body
depends one users setting) :
IPPOWERCTRL:TAG=148ON;POWER1=OFF;POWER4=ON;POWER8=ON