![Avio iP-01BE Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/avio/ip-01be/ip-01be_user-manual_3031798017.webp)
E-17
Please use the following diagrams to determine the screen display size and the type of screen required for any
given projector location.
Projection distances that will be in focus will be 0.67 m (2.2 feet) to 6.1 m (20.0 feet) from the front of the lens.
Please arrange the setup within this range.
Projection Distance and Screen Size
Wide: The size of the projection image
becomes maximum with the pro-
jection image size adjustment us-
ing the zoom lens
Tele: The size of the projection image
becomes minimum with the pro-
jection image size adjustment us-
ing the zoom lens
B
A
Screen Size
When the zoom lever is at maximum on the telephoto side
When the zoom lever is at maximum on the wide side
200 inches (approximately 4.0 x 3.0 m)
300 inches (approximately 6.0 x 4.5 m)
100 inches (approximately 2.0 x 1.5 m)
80 inches (approximately 1.6 x 1.2 m)
60 inches (approximately 1.2 x 0.9 m)
Projection Distance Table
Screen size
(inches) op-
posite angle
Screen Size
A: Projection distance (m) B: Height of
projection bot-
tom edge (mm)
Height (mm)
Wide
Telephoto
300
6.0×4.5m
6.1
−
661
4572
200
4.0×3.0m
4.1
4.9
441
3048
100
2.0×1.5m
2.0
2.4
220
1524
80
1.6×1.2m
1.6
1.9
176
1219
60
1.2×0.9m
1.2
1.5
132
914
40
0.8
1.0
88
609.6
CAUTION
Setup Location
• Do not place the projector in locations that will reach high temperatures or low temperatures.
Operation ambient temperature: 0°C (32°F) to 35°C (95°F)
• Set the screen so that it is not exposed to direct sunlight or the light of direct illumination. When light hits the
screen, the screen show a white cast and will be difficult to watch.
In a bright room, the curtains should be drawn or blinds closed and the area around the screen kept dark.
• Do not set up the projector in locations exposed to dampness, dust, greasy smoke or tobacco smoke.
Doing so will result in the adhesion of dirt to lenses, mirrors, and other optical parts and cause a degradation
of image quality.
• Do not place the projector in a location where the ventilation vents will be blocked or in closed areas having
poor ventilation. Doing so will cause the temperature to rise and could cause a fire or accident. (The exhaust
vents are at the front of the projector and the air intake vents are located at the side.)
• Do not place the projector at a location where it may be propped up or swayed.
• During unit operation, do not obstruct the front of the lens. During operation, strong light is projected through
the lens and if the front of the lens is obstructed by a matter or hand, it may cause fire or burn.
• During projection, be sure to remove the lens cap. The lens cap may be deformed.
• Please do not set the projector on a table or desk mat made of a heat-sensitive material. Table may be dis-
colored or desk mat may be deformed.