Regulatory

Prior to installation, it is necessary to find a suitable site indoors (this product should always be installed indoors).
It is assumed that the installer has required certifications and required permits. The Installer must follow electrical
standards and AHJ requirements.

All National and local Electrical codes apply.

l

This equipment is intended to be powered from a limited power source output of a previously certified
power supply.

l

Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.

Class A Digital Devices

FCC Compliance Statement:

This equipment has been tested and found to comply with the limits for a Class A

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.

Canada Class A

CE Mark – Europe (EU)

C-Tick – Australia and New Zealand

VCCI – Japan

NCC — Taiwan

SRRC— China

IDA — Singapore

KCC — Korea

UL Recognized Component (UL294 and UL1076)

RoHS compliant

3

Содержание AC-ACMEC-KIT16

Страница 1: ...Installation Guide Avigilon 16 Door ACM Embedded Controller Kit AC ACMEC KIT16 ...

Страница 2: ...opyright industrial design trademark patent or other intellectual property rights of Avigilon Corporation or its licensors This document has been compiled and published covering the latest product descriptions and specifications The contents of this document and the specifications of the products discussed herein are subject to change without notice Neither Avigilon Corporation nor any of its affi...

Страница 3: ...nt This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with...

Страница 4: ...O75 Power Supply Board 12 Setup the D8P Power Supply Boards 13 Setup the C8 Power Supply Boards 14 Install the ACM Embedded Controller and V100 Subpanels 16 Configure and Wire Data 18 Configure and Wire Power 21 Power On 25 Accessing ACM Embedded Controller Application for the First Time 26 By Virtual Port 26 By Host Name 26 Checklists 27 Tools Checklist 27 Equipment Checklist 27 4 ...

Страница 5: ...r interface which links to the ACM Embedded Controller application The application allows you to effectively control access at each entry point Package Contents The package contents for the 16 Door ACM Embedded Controller are l One AC LSP 16DR HID LCK LifeSafety Power eight door HID dual voltage integrated power system shipped in a separate box l One Avigilon AC HID ACMEC V1000 ACM Embedded Contro...

Страница 6: ... this document and gather the required information before proceeding with these instructions CAUTION The controllers and interface panels are sensitive to Electrostatic Discharges ESD Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all times Installation 6 ...

Страница 7: ...weighs 22 2kg 49lb 3 Mount the plywood board onto the wall at the desired location NOTE It is highly recommended that the plywood board is mounted to two studs If no studs are available use appropriate drywall anchors that can support the enclosure 4 Remove one of the two high voltage knockouts 5 Attach an appropriate cable gland to the 7 8 diameter high voltage opening 6 Mount the enclosure to pl...

Страница 8: ...gh two white two black one ground 2 3 1 KEY 1 is a sample high voltage junction box while 2 and 3 are sample cable glands CAUTION Do not connect to the main power supply yet 8 Remove knockout s for low voltage input output wires as necessary 9 Attach an appropriate cable gland to each 1 3 8 diameter low voltage opening Mounting the ControlPanelCase 8 ...

Страница 9: ...Power Supply Board Overview Shown below is an overview of the power supply board FPO250 D8P D8P C8 C8 FPO75 9 Power Supply Board Overview ...

Страница 10: ... 1 Either l For 120V input leave JP1 intact l For 230V input cut JP1 CAUTION Failure to cut this jumper when using the FPO with a 230VAC input will result in damage to the system and will void the warranty 2 Ensure DC output switch is set to 24V as shown below Setup the FPO250 Power Supply Board 10 ...

Страница 11: ...information is available at http lifesafetypower com docs im_fpo pdf 4 Either l If a backup battery is used move the jumper to position 1 as shown below l If no backup battery used move the jumper to position 2 NOTE If using battery backup then a separate enclosure is required for the batteries due to space limitations in this enclosure 11 Setup the FPO250 Power Supply Board ...

Страница 12: ... CAUTION Failure to cut this jumper when using the FPO with a 230VAC input will result in damage to the system and will void the warranty 2 Ensure the DC output jumper is set to 12V as circled below CAUTION Failure to set the FPO75 s DC output jumper to 12V will likely result in damage to the system and will void the warranty Setup the FPO75 Power Supply Board 12 ...

Страница 13: ... batteries due to space limitations in this enclosure Setup the D8P Power Supply Boards On both D8P boards set all output voltage selection jumpers JP1 to 8 to provide 12VDC See the D8 Quick Start Manual or D8 D8P Installation Manual for more detail available at http www lifesafetypower com docs im_d8 pdf CAUTION Failure to set the JP1 to 8 jumpers may cause damage to components 13 Setup the D8P P...

Страница 14: ... 1A to 8A Zone FAI enabled Either 1 FAI enabled 2 FAI disabled Blue 1B to 8B Input Invert Either 1 Fail Safe NC contact input 2 Fail Secure NO contact input Black 1C to 8C Wet Output Selection Either 1 Relay Contact Output 2 Voltage Output Yellow 1D to 8D Voltage Bus Selection Either 1 B1 Bus 2 B2 Bus Setup the C8 Power Supply Boards 14 ...

Страница 15: ...tput White 1F to 8F Output Invert Either 1 NO voltage when input is activated 2 NC voltage when input is deactivated See the C4 C8 Quick Start Manual or C4 C4P C8 C8P Installation Manual for more detail available at http www lifesafetypower com docs im_c4c8 pdf 15 Setup the C8 Power Supply Boards ...

Страница 16: ...0 subpanels 2 Locate 12 screws and 24 Hex nuts from the accessory bag in the FlexPower box 3 Verify battery jumper Batt on the ACM Embedded Controller has been set to ON position CAUTION This is a non PoE device Do not connect J1 Ethernet port to a PoE capable port This applies to both direct PoE Power Sourcing Equipment Endspan PSE and PoE injector Midspan PoE equipment Not all PSE s correctly de...

Страница 17: ...ess 6 V100 Address 5 V100 Address 4 V100 Address 3 V100 Address 2 6 Using a small slotted screwdriver gently turn the V100 addresses as follows l Ensure the V100 mounted directly below the ACM Embedded Controller is at Address 0 l Set the other V100 on the back plate of the case enclosure to Address 1 l Set the other V100 s mounted on the door as per the picture in the previous step Address 2 to 7...

Страница 18: ...arity does not matter ACM EMBEDDED CONTROLLER 4 Using 18 AWG wires red for and black for wire the 12 24VDC input to Out1 on the D8P board s terminal block ACM Embedded Controller Tamper Input 5 AC Fail Input 6 Batt Fail Input 7 12 24VDC IN D8P OUT 8 7 6 5 4 3 2 1 5 On the FPO250 s SYSFLT terminal block l Wire C to Batt Fail 22AWG l Wire NO to Batt Fail 22AWG ACM Embedded Controller Tamper Input 5 ...

Страница 19: ...5 s SYSFLT terminal block l Wire C to Batt Fail 22AWG l Wire NO to Batt Fail 22AWG V100 Address 0 Tamper Input 5 AC Fail Input 6 Batt Fail Input 7 12VDC IN FPO75 SYS FLT AC FLT FAI INPUT C NC NO C NC NO 9 On the FPO75 s ACFLT terminal block l Wire C to AC Fail 22AWG l Wire NO to AC Fail 22AWG V100 Address 0 Tamper Input 5 AC Fail Input 6 Batt Fail Input 7 12VDC IN FPO75 SYS FLT AC FLT FAI INPUT C ...

Страница 20: ...D CONTROLLER P3 RS 485 Port 1 V100 Addr 0 A B Shield P9 RS 485 In V100 Addr 6 A B Shield P9 RS 485 In V100 Addr 4 A B Shield P9 RS 485 In V100 Addr 5 A B Shield P9 RS 485 In V100 Addr 1 A B Shield P9 RS 485 In V100 Addr 7 A B Shield P9 RS 485 In V100 Addr 2 A B Shield P9 RS 485 In V100 Addr 3 A B Shield P9 RS 485 In NOTE On the V100s make sure to use the RS 485 In avoid using the RS 485 Out Config...

Страница 21: ...dr 0 V100 12VDC to Out1 and to Out1 l Connect the Addr 1 V100 12VDC to Out2 and to Out2 l Connect the Addr 2 V100 12VDC to Out3 and to Out3 l Connect the Addr 3 V100 12VDC to Out4 and to Out4 l Connect the Addr 4 V100 12VDC to Out5 and to Out5 l Connect the Addr 5 V100 12VDC to Out6 and to Out6 l Connect the Addr 6 V100 12VDC to Out7 and to Out7 l Connect the Addr 7 V100 12VDC to Out8 and to Out8 ...

Страница 22: ...Input 6 Batt Fail Input 7 12VDC IN Connections on the case enclosure door Note For the steps that ensure that the card reader door monitor if available request to exit if available and lock wiring from the door are fed into the power supply enclosure and route to the corresponding port on each V100 as desired 5 If door monitor inputs are available connect them appropriately to the P2 Door Monitor ...

Страница 23: ...ion left OUTPUTS 1A 8B INPUTS 1A 8B To Door Locks To V100s Addresses 0 3 INPUT 1A 1B INPUT 2A 2B INPUT 8A 8B INPUT 7A 7B INPUT 6A 6B INPUT 4A 4B INPUT 3A 3B INPUT 5A 5B Address 0 Address 3 Address 2 Address 1 right OUTPUTS 1A 8B INPUTS 1A 8B To Door Locks To V100s Addresses 4 7 INPUT 1A 1B INPUT 2A 2B INPUT 8A 8B INPUT 7A 7B INPUT 6A 6B INPUT 4A 4B INPUT 3A 3B INPUT 5A 5B Address 4 Address 7 Addre...

Страница 24: ...s desired see the C4 C8 Quick Start Manual or C4 C4P C8 C8P Installation Manual for more detail available at http www lifesafetypower com docs im_c4c8 pdf 9 Wire both C8 board s outputs 1 to 8 to their corresponding door locks See theC4 C8 Quick Start Manual or C4 C4P C8 C8P Installation Manual available at http www lifesafetypower com docs im_c4c8 pdf Configure and Wire Power 24 ...

Страница 25: ...ll warning lights see 2 above should be off 2 Connect the battery set s if applicable See the FPO Quick Start Manual page 1 Battery Terminal Connection for more detail Further information is available at http lifesafetypower com docs im_ fpo pdf NOTE If using battery backup then a separate enclosure is required for the batteries due to space limitations in this enclosure CAUTION Observe battery po...

Страница 26: ... x x address 5 Open a web browser and enter this address 169 254 242 121 The controller is now accessible through this virtual port 6 Enter your login for the application The default username and password is admin By Host Name To access the ACM Embedded Controller application by this method your DHCP server must support hostname access and only have one controller in the local area network LAN 1 M...

Страница 27: ...e cutter Required Wire stripper Required Laptop Recommended Multi meter Optional Equipment Checklist The following equipment is provided Tool Required Recommended Optional One AC LSP 16DR HID LCK LifeSafety Power 16 door HID dual voltage integrated power system supplied in a separate shipping box Required One Avigilon AC HID ACMEC V1000 ACM Embedded Controller Required Eight AC HID VERTX V100 read...

Страница 28: ...pening Required One plus cable gland s for 1 3 8 low voltage opening Required 18 AWG stranded wiring Required 22 AWG stranded wiring Required Ethernet Cat5e cable Required One to two sets of 2x 12V backup batteries in series to deliver 24V power Optional Backup batteries provide the ability to power the system in case of power outage For more information refer to Section 3 Specifications of the DC...