background image

UNIVERSAL CONNECTED CONTACTOR

EN

12

F - USING THE PRODUCT

1 - USE VIA THE APPLICATION

Warning:

 Thanks to the position of the magnets, 

the contactor can indicate whether or not your gate 
is closed. When the app indicates that the gate is 
open, it means that the two magnets are no longer 
in contact with each other. This does not however 
guarantee that the gate is actually completely 
open. In the event of faulty operation (e.g.: obstacle 
detection, motor error, etc.), if the gate remains ajar 
the contactor cannot be held responsible.

IMPORTANT:

 The dry contact signal is the same 

whether the opening or closing of the gate is 
triggered. The contactor will take into account the 
last command given as well as the position of the 
magnets to determine the current command to be 
displayed in the app.

However, control logics are specific to each 
manufacturer and subject to different settings. 
Therefore the contactor does not know exactly the 
operating status of the gate motor drive when it is 
moving, or what the control logic will require the 
motor drive to do when a new command is given. 

As a result, it is possible that the gate may move in 
the opposite direction to what the app is indicating. 
(e.g.: automatic closing activated, motor drive 
behaviour after a switch to safety mode, “stop” 
command while in motion, control by a third party 
device, etc.). In any event, wait until the end of the 
app’s display to determine the status of the gate 
(closed or not closed). 

1

2

4

3

6

5

1

Gate position status (display when in 
operation) in relation to the magnets 

2

Alert setting and operating time prior to alert

3

Countdown to contact trigger

4

Command trigger button

5

History of opening/closing requests

6

Time programming of contact triggers

Press the command trigger button in the app. The 
contactor will send the command order to the 
motor drive. The opening or closing display will start 
within the given deadline. If your motor drive fails to 
complete its cycle within the determined operating 
time, go to the 

Alarm

 setting (2), then 

close 

reminder.

 Adjust the cycle time of your automatic 

gate. 

When the determined operating time is exceeded, if 
the magnets did not separate during opening, or if 
the magnets did not come together during closing, 
the app displays this message.

2 - USING THE PRODUCT WITH GOOGLE 
HOME

Note:

 the name you give your Avidsen Home 

devices is the one that will be recognised by Google 
Assistant. 
Example: if you have a contactor named “gate”, “OK 
Google, open gate” will work, whereas “OK Google, 
open motor drive” may not trigger
anything.

Содержание 127041

Страница 1: ...UNIVERSAL CONNECTED CONTACTOR HOME GATE Ref 127041 www avidsen com V3 ...

Страница 2: ...05 4 RECYCLING 05 B PRODUCT DESCRIPTION 06 1 KIT CONTENTS 06 2 CONNECTED CONTACTOR 06 C INSTALLATION 07 1 INSTALLATION ON SLIDING GATE 07 2 INSTALLATION ON SWING GATE 07 3 GARAGE INSTALLATION 07 D WIRING 8 E CONNECTION 9 1 INSTALLING THE MOBILE APPLICATION AND CREATING AN ACCOUNT 9 2 CONNECTING THE CONTACTOR 10 ...

Страница 3: ...OOGLE HOME 13 3 USING THE PRODUCT WITH AMAZON ALEXA 14 4 SCENARIO AND AUTOMATION 14 4 1 SCENARIO 14 4 2 CREATING AN AUTOMATION 15 G TECHNICAL AND LEGAL INFORMATION 21 1 TECHNICAL CHARACTERISTICS 21 2 RADIO CHARACTERISTICS 21 3 WARRANTY 22 4 HELP AND ADVICE 22 5 PRODUCT RETURNS AFTER SALES SERVICE 22 6 EC DECLARATION OF CONFORMITY 22 ...

Страница 4: ...EN 4 ...

Страница 5: ...s activation with visible gate Minimum level of protection Force limiter only Press activation with non visible gate Minimum level of protection Force limiter and 2 pairs of photocells to protect the gate s opening and closing Automatic control automatic closure Minimum level of protection Force limiter and 1 pair of photocells to protect the gate s automatic closing Care should therefore be taken...

Страница 6: ...g will determine the complete or partial opening of the gate pedestrian mode For the product to work it must have a WiFi connection 2 CONNECTED CONTACTOR 1 Connected contactor 2 Passive magnet 3 Pre wired magnet with extension 4 Magnet brackets 5 Grommet 6 Screw Nut 7 Double sided tape 8 Double sided tape 9 Quickstart 1 x 1 2 x 1 4 x 2 3 x 1 5 x 4 6 x 2 9 x 1 7 x 2 8 x 1 1 5 4 2 3 1 Operation indi...

Страница 7: ...nction box 1 INSTALLATION ON SLIDING GATE Put the gate in closed position Attach the passive magnet to the gate Install the magnet bracket on the ground leaving a gap of no more than 13mm between the magnets The magnets must not touch 2 INSTALLATION ON SWING GATE Passive magnet Grommet Electronic card Contactor Waterproof housing Pre wired magnet Install the pre wired magnet on the panel on the si...

Страница 8: ...breaker in OFF position before making the 230V connection Do not run the magnet and control cables in direct proximity to 230V cables Risk of signal disruption due to induction AC IN 230V AC L N Gate or garage door motor drive Avidsen HomeGate Dry contact input ...

Страница 9: ...oad the Avidsen Home app from the Android Play Store or Apple App Store Launch the app and log in if you already have an account If not press CREATE A NEW ACCOUNT and let the application guide you After accepting the privacy policy create an account with an email address Procedure by email In a few seconds you will receive a validation code in your email inbox Enter this code to finalise registrat...

Страница 10: ... the application Select the product you wish to pair and select Home Gate Make sure the contactor is connected and its blue indicator light is flashing Otherwise press the reset button for 5s so that the blue indicator light starts flashing Select your 2 4GHz WiFi network note your smartphone must be connected to the WiFi network to which the plug will be connected enter your network password and ...

Страница 11: ...quency then click on Continue Please wait while the pairing procedure takes place This stage can last several minutes Your contactor is now operational and will appear in your app You can now control your Avidsen contactor from your smartphone You can rename it by clicking on the small pencil to the right of the device name garage by default ...

Страница 12: ...the app is indicating e g automatic closing activated motor drive behaviour after a switch to safety mode stop command while in motion control by a third party device etc In any event wait until the end of the app s display to determine the status of the gate closed or not closed 1 2 4 3 6 5 1 Gate position status display when in operation in relation to the magnets 2 Alert setting and operating t...

Страница 13: ...istant Connect devices to Google Assistant On your Android phone or tablet press and hold the home button or say OK Google In the lower right hand corner press Press the logo on the upper right then Paramètres Settings then Assistant and finally Contrôle de la maison Control from home In the Appareils Devices tab press Ajouter des appareils Add devices Select the Avidsen Home app then follow the i...

Страница 14: ...an automated device Once a skill is installed say Alexa find new devices After 45 seconds Alexa will give you the devices found For more information on Amazon Alexa please consult Amazon support One tip however if you connect multiple modules within the same zone and to prevent unwanted commands we recommend you do not use the group name suggested by Alexa bedroom office living room etc when namin...

Страница 15: ...lready been saved and enable or disable it while the new scenario is running 4 2 CREATING AN AUTOMATION The automation system in the Avidsen Home app allows you to group devices and actions which will be triggered automatically by the action of another device or a condition temperature time etc Example creating a Gate opening automatic action that triggers a contact at a given time only if the gat...

Страница 16: ...nditions are met corresponds to an ET AND function If Temperature x ET AND time y ET AND device n then Lorsque l une des conditions est remplie When one of the conditions is met corresponds to a OU OR function If Temperature x OU OR time y OU OR device n then After selecting the condition type choose the conditions themselves 1 3 5 7 2 4 6 1 Set a temperature weather condition 2 Set a humidity wea...

Страница 17: ...e of actions 5 Set an action on a device already recorded in the app The last setting allows you to define a time slot during the day if necessary during which to authorise the automation launch Once all these settings have been confirmed you can save your automation at the top right 4 2 1 PROGRAMMING THE GATE OPENING AUTOMATION The automatic action in this example will allow the user to open thei...

Страница 18: ...the opening time Slide your finger up or down the time column in the minute column The time configured will appear between the two parallel lines You can ask for a repeat of the scenario on different days of the week To configure this click on Repeat The conditions have been created Select the When all conditions are met variable ...

Страница 19: ...NNECTED CONTACTOR EN 19 F USING THE PRODUCT Next you need to determine the action to be performed Rename your scenario at your convenience in our example GATE OPENING Once all parameters have been set click on Save ...

Страница 20: ...UNIVERSAL CONNECTED CONTACTOR EN 20 F USING THE PRODUCT If you wish to access the details or delete it click on the icon at the top right of its name ...

Страница 21: ... 10 m through 1 wall floor max Radio range for plasterboard wood 30 m through 5 walls max Max power 200W Features Opens gates and garage doors Connection Wired 1 output Cable cross section Up to 1 5mm2 Use Indoors and outdoors Operating temperature 10 C 50 C Storage temperature 20 C 70 C Power supply 230 Vac 50 Hz Average consumption 1W Position sensor 5m cable Maximum distance between sensors 10m...

Страница 22: ...en contacting us so that one of our technicians can diagnose the source of the problem as it will probably be the result of a setting that is incorrect or an installation that is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may refuse to exchange the produc...

Страница 23: ...Avidsen 19 avenue Marcel Dassault ZAC des Deux Lions 37200 Tours France ...

Отзывы: