Power Cords
47
Power Cords
Select the power cords for the MEDIArray ZX4 according to the country
destination; it must comply with local safety requirements.
w
The power cords are the MEDIArray ZX4 power disconnect device, and
if rack mounting renders the power cords inaccessible, then the rack must
provide a means to disconnect power.
w
The Power switch on the front of the MEDIArray ZX4 is a “standby”
switch only. It does not disconnect power from the components inside the
MEDIArray ZX. If you need to service the MEDIArray ZX, disconnect
both power cords before beginning the service operation.
Use the following guidelines to replace the original cord set:
•
CEE-22 requirements:
The female receptacle of the cord set, shown
below, must comply with CEE-22 requirements.
Receptacle (CEE-22)
•
United States and Canada requirements:
In the United States and
Canada, the male plug is a NEMA 5-15P style and is UL listed and CSA
certified. The following figure shows the plug. SVT cordage can be used
with desktop, countertop, or rack-mount units; all other equipment
requires SJT cordage. Only SJT-type cord sets can be used for units that
sit on the floor.
Select the cord set according to the current rating of your unit. See the
following table for the selection criteria for power cords in the United
States and Canada.