AVG-UHD4K-44 V2
HDCP Compliance
Command
Function
Feedback Example
/%[Y]/[X]:[Z].
HDCP management command.
Y=O is for output;
X=1~4 is the number of the port, if the
X=ALL, it means all ports;
Z is for HDCP compliant status, the value
may be 1 (HDCP compliant) or 0 (not
HDCP compliant).
/%O/ALL:0.
%0801.
Auto HDCP management, activate carrier
native mode
%0801
%9973.
Report the HDCP status of the inputs.
In 01 02 03 04
HDCP Y N Y N
%9974.
Report the HDCP status of the outputs.
Out 01 02 03 04
HDCP Y N Y N
EDID Configuration
The DIP switch status should be set as 1111 to enable Software EDID management
mode: RS232 control or Web-based GUI control.
Command
Function
Feedback Example
EDIDH[x]B[y].
Copy the EDID of output [x] to input [y].
If the EDID data is available and the audio
part supports not only PCM mode, then
force-set it to support PCM mode only. If the
EDID data is not available, then set it as
initialized EDID data.
EDIDH1B1
EDIDPCM[x].
Set the input [x] audio to PCM format in
EDID database, x=1~4.
EDIDPCM[x]
EDIDG[x].
Report EDID data from output [x], x=1~4.
Hexadecimal EDID data
and carriage return
character
EDIDMInit.
Restore the EDID factory default.
EDIDMInit.
EDIDM[X]B[Y].
The input [Y] learns the EDID data of output
[X]. If the EDID data is not available, then
set it as initialized EDID data.
EDIDM3B1
EDID/[x]/[y].
Set the built-in EDID data type [Y] to input
port [X]. y= 0~11, correspond to the 12
embedded EDID data separately.
EDID/[x]/[y]
EDIDUpgrade[x].
Upgrade the EDID data of the input [x].
When the command applied, system
prompts to upload the EDID file (.bin).
Operation will be cancelled in 10 seconds.
Please send the EDID
file
EDID Upgrade OK!
GetInPortEDID[X].
Report the EDID data of input [x], x=1~4.
%9979.
Report the DIP switch status.
EDID RS232 GUI
CONTROL 1111