ZM305 GTN Inbound-Outbound User Instructions
55
7.4 Battery
7.4 Battery
Super
Setpoint
Tare
Truck
Battery
1.
From
trucK
, press
UNITS
…
bAttErY
is displayed. Use this to enable the battery and to set a timeout
length (in minutes). If this time expires with no scale or keypad activity,
setpoint #3 will change states so the battery will shut off if the proper
external circuitry is provided. See the Service manual.
Enable
Battery
Enable
2.
Press
SELECT
…
EnAbLE
is displayed. Choices are
oFF
and
on
. Choose
oFF
to disable
battery usage. Choose
on
to enable battery usage.
3.
Press
UNITS
to toggle between the choices and when your choice is
displayed, press
ZERO
to accept …
EnAbLE
is displayed.
Timeout
Battery
Enable
Timeout
4.
Press
UNITS
…
tMout
is displayed. This stands for timeout. Use this to set the length of
time before inactivity of the scale and keypad cause battery power to be
shutoff. Values between 1 and 3600 minutes are valid.
This function
only works if the battery has shutoff circuitry.
5.
Press
SELECT
…
A numeric entry screen appears.
6.
Key in a value, in minutes and press
ZERO
to accept …
tMout
is displayed.
7.
This completes the Supervisor menu for General Weighing. Repeatedly press
TARE
until the indicator returns to normal weighing mode.
The current weight value is displayed.
Only enable the battery and set the
tMout
value if the battery has the proper external
shutoff circuitry. If battery use is enabled, setpoint output 3 cannot be used for
setpoints in any application. It is used as a shutoff signal.