Avery Weigh-Tronix QC-3265 Скачать руководство пользователя страница 11

11

QC-3265 Checkweigher User’s Manual

User Menu

Without realizing it you have learned how to access the User menu. When
you press the 

>

 key from either the checkweighing (deviation display) or the

weighing (weight display) mode you access the User menu shown below.

You have already learned about 

UNDER  

and 

OVER 

tolerance. The other

items in this menu are described below.

OFF

This item appears only if battery power mode is enabled in setup,
With 

OFF 

displayed, press the 

key to turn off the QC-3265.

Pressing any key turns the unit on in weight display mode. Battery
power is not an option with QC-3265s equipped with an LED
weight display.

ABOUT

Press the 

key with 

ABOUT 

displayed and 

QC3265 

will be

displayed. Press the 

>

 key to step through the EPROM part

number, dash number, revision letter, and then back to 

QC3265

.

Press the 

^

 key to go back to the 

ABOUT 

display.

TEST

Press the 

key with 

TEST 

displayed to access the test menu

shown in Figure 3. Use the 

v

,

 ^

,

 <

 

and

 > 

keys as before to move

through the menu.

AUDIT

Lets you see the CA (calibration) audit number and the

CF (configuration) audit number.

DISP.

Press the 

v

 key twice to perform a display segment

test. Press the 

or 

>

 key to change the direction of the

test. Press the 

^

 key twice to stop the test and return

to 

DISP.

Figure 2

User Menu

Move to the right by pressing the 

key

Move down by pressing the 

key

Move left by pressing the 

key

Move up by pressing the 

key.

Содержание QC-3265

Страница 1: ...QC 3265 Checkweigher User s Manual...

Страница 2: ...3265_U P65 PN 29600 0011J e1 Printed in USA Risk of electrical shock Do not remove cover No user service able parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the righ...

Страница 3: ...and Operation 9 Installation 9 Explanation of Modes of Operation 9 Operation as a Scale 9 Gross Weight Checkweighing 10 Net Weight Checkweighing 10 Changing the Acceptance Tolerance 11 User Menu 11 Co...

Страница 4: ...V C Span 5 0 ppm C 10 ppm C For scale base 3000 divisions 0 005 of capacity maximum For base 0 01 0 005 of capacity maximum For base 0 01 0 005 of capacity maximum For base 0 01 All calibration and p...

Страница 5: ...00 x 02 3 x 0005 3000 x 5 12 x 005 200 x 0 1 6 x 002 6000 x 2 12 x 002 200 x 0 05 6 x 001 6000 x 1 30 x 01 480 x 0 2 15 x 005 15000 x 5 30 x 005 480 x 0 1 15 x 002 15000 x 2 60 x 02 960 x 0 5 30 x 01...

Страница 6: ...6 QC 3265 Checkweigher User s Manual This page left intentionally blank...

Страница 7: ...Weigh Tronix distributor Figure 1 shows the front panel The panel consists of the following a six digit liquid crystal or LED display five keys QUICK CHECK TARGET UNITS ZERO Right arrow key a center...

Страница 8: ...of measure is enabled Use this key to move to the left in the menus Use the ZERO down arrow key to zero the scale while in either display mode In the A D test mode this key sets the offset to zero Us...

Страница 9: ...rs up in weight display mode if there is no target weight in memory Use the checkweigh mode for checkweighing operations and the use of the OVER ACCEPT and UNDER LEDs If there is a target weight in me...

Страница 10: ...mea sure and division size The over LED is lit 3 Press the key to decrease the value and the key to increase the tolerance value Press the v key to accept the displayed value OVER is displayed 4 Pres...

Страница 11: ...ipped with an LED weight display ABOUT Press the v key with ABOUT displayed and QC3265 will be displayed Press the key to step through the EPROM part number dash number revision letter and then back t...

Страница 12: ...ulator A to D Shows the output of the A to D converter with a sensitivity of 20 000 counts per millivolt per volt SERIAL Lets you perform READY BUSY and LOOP NOLOOP tests to check the serial port READ...

Страница 13: ...e is detected This appears when voltage level reaches 10 5 volts and alternates with the normal display The unit will shut itself off at 9 2 volts Only available on battery powered units Communication...

Страница 14: ...Installation for USDA Approved Applications Figure 4 Plastic knob installation Below are the instructions and illustration for installing the plastic knobs which are necessary for USDA approved insta...

Страница 15: ...irmont MN 56031 USA Telephone 507 238 4461 Facsimile 507 238 4195 e mail industrial weigh tronix com www wtxweb com 217 Brunswick Blvd Pointe Claire QC H9R 4R7 Canada Telephone 514 695 0380 Facsimile...

Отзывы: