6.2 Remote Display Modes: (Serial Port Settings – Host Indicator)
The first character can be a G or N for Gross or Net weight active value. This is followed
by a space <SP> and a six digit numeric weight followed by another space <SP>. The
serial string will end with the current unit of scale measure <UN> and the end of
message character <CR>, carriage return, followed by a line feed <LF>. Refer to figure
#1 for host output protocol.
The remote display can also transmit key presses, for basic weight functions, back to
the host indicator. Functions include; Print, Zero and Tare. Refer to Table 3 for remote
key press protocol.
6.1.4 Mode 4: Remote weight display with keypad and annunciators
The host sends the same serial string as mode 3, but the addition of annunciator
information will be present in the serial string from the host. Mode 4 contains the string
G<SP>00000<SP>lb<CR><AN1><AN2>…<ANn><CR><LF>
Refer to figure #1 for host output protocol. The first character can be a G or N for Gross
or Net weight active value. This is followed by a space <SP> and a six digit numeric
weight followed by another space <SP>. The serial string will end with the current unit
of scale measure <UN> and the end of message character <CR>, carriage return.
Annunciators are mapped according to the bit table, figure #2, and transmitted from the
host indicator to the remote display after the end of message character.
The remote display can also transmit key presses, for basic weight functions, back to
the host indicator. Functions include; Print, Zero and Tare. Refer to Table 3 for remote
key press protocol.
6.2
Remote Display Modes: (Serial Port Settings – Host
Indicator)
There should be five modes of operation for the remote display Serial Port/setting.
(This only describes Remote display modes. There may be more serial modes such as
RS-485, ENQ…)
6.2.1 Mode 4100: Remote weight display only
This is a serial port mode which will send a configured print format, at the display
update rate, to an Avery Weigh-Tronix RD 4100 remote display. The print format can
be edited to allow communications to any remote display.
6.2.2 Mode 1: Remote weight display only
Mode 1 sends G<SP>00000<SP>lb<CR><LF> at the display update rate. The remote
indictor will display Gross or Net weight values only.
6.2.3 Mode 2: Remote weight display with annunciators
Mode 2 sends G<SP>00000<SP>lb<CR> <LF><AN1><AN2>…<ANn> <CR><LF> at
the display update rate. The remote indicator will display weight and annunciators such
as; motion, center of zero, outputs or annunciators specific to a configured application.
Содержание E1070
Страница 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Страница 6: ...6 E1070 Service Manual ...
Страница 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Страница 146: ...146 E1070 Service Manual 8 Network Connections ...
Страница 149: ...E1070 Service Manual 149 10 Complete Menu Structures 10 1 Complete Supervisor and User Menus Supervisor Menu User Menu ...
Страница 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Страница 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Страница 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Страница 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Страница 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Страница 162: ...162 E1070 Service Manual ...
Страница 163: ......