03/13 Rev. 5.08-01
USER MANUAL
Einrichten
64-xx – 64-xx dispenser
18
Information about operation with start signal can be found in topic section
Advanced Applications
, chapter „Printing with start signal“.
Parameter settings for „64-xx dispenser M“
The printing/dispensing process can be triggered by foot switch or by
light barrier:
Foot switch
The values preset by the manufacturer (see tab. 3) are valid for manual
triggering of the printing/dispensing via the Single-Start connector, e.g.
using a foot switch. After pressing the foot switch, one label is printed and
dispensed.
Set
DISPENSER PARA > Start source
to „
Foot switch
“.
Light barrier
The dispensed label triggers a light barrier. This stops the printing/
dispensing until the user takes the label off. Then, the printer moves the
material back under the print head (only if „Real 1:1 Mode“ is selected,
see parameter
DISPENSER PARA > Dispense Mode
) and prints and dispenses
the next label.
Change the basic parameter setting as follows to use the light barrier for
triggering:
Set
DISPENSER PARA > Start source
to „
Light barrier
“.
Parameters settings for „64-xx dispenser A“
„64-xx dispenser A“ is equipped with a longer dispensing edge which lea-
ves enough space for closing the hood if an applicator is mounted. This
long dispensing edge has no light barrier.
Applicator
The „64-xx dispenser A“ is designed to be used with the LTSI applicator.
Advice on printer operation with the LTSI applicator, see
Service manual
LTSI
.
Advice on setting parameters can be found in topic section
Info printouts
and parameters
.
Information about operation with start signal can be found in topic section
Advanced Applications
, chapter „Printing with start signal“.