12/14 Rev. 03
USER MANUAL
Commissioning & Operation
64-xx
12
Switching on the printer
Turn on the printer using the power switch (set to position “1”). The following
sequence of messages is displayed:
If the parameter
SYSTEM PARAMETER > Turn-on mode
is set to “Offline”, the printer
switches directly to offline mode when turned on.
CAUTION! - Wait at least 10 seconds between switching the device off and
on again, otherwise any modified parameter settings are not saved.
Configuring the data interface
By factory default, the 64-xx is set for data transfer via the USB interface.
Print data can also be transferred via the RS232, RS422/485
1
, USB,
Centronics
2
or Ethernet interface.
Choosing the port:
INTERFACE PARA >EASYPLUGINTERPR > Interface
Configuring the port:
•
RS232:
INTERFACE PARA >COM1 PORT > ...
•
RS232/422/485 (optional):
INTERFACE PARA >COM3 PORT > ...
•
Ethernet:
INTERFACE PARA >NETWORK PARAM. > ...
We recommend that your network administrator configures the network
settings.
•
USB: no configuration required
Setting parameters
: see topic section „Info-Printouts and Parameters“,
chapter “Using the Parameter Menu”.
Ethernet interface
: Information about using it can be found in topic section
„Advanced Applications“.
System start...
The boot loader is starting.
System start...
Start user prog
Valid firmware recognised, program is starting.
64-05
V 6.52
Printer type
Version number of the printer firmware
Memory: 64 MB
Flashcard: 32 MB
Internal RAM (here: 64 MB)
Optional RAM on the memory medium (here: 32 MB)
– only displayed if a memory medium (memory card
or USB stick) is connected.
OFFLINE 0 JOBS
Initialisation
Offline mode
ONLINE 0
JOBS
Online mode. The unit is ready for printing.
1) Only with installed I/O interface board (option)
2) Only with installed Centronics interface board (option)