10
UV Lamp Panel Setup
1. Select
the
Auto/Manual Mode Slide Switch
to start disinfecting automatically
or manually.
a. If
Auto
mode is chosen, close the front and rear doors and disinfecting will
start in 30 seconds.
b. If
Manual
mode is chosen, close the front and rear doors and press
Start/Stop Button
to begin disinfecting. Press
Start/Stop Button
to stop
disinfecting.
c. Auto/Manual modes can be reselected even during disinfecting. The UV
lamps will turn off and reset as the new selected mode.
[Note]
Four sensors are installed at front and rear doors. If the front or rear
doors are open during disinfecting, the UV lamps will automatically turn off to
protect the user’s eyes/skin.
2.
UV Setup LED Status
Status
Description
Solid Green
Front doors and rear doors are closed. Ready for
disinfecting.
Solid Blue
Manual mode:
Press Start/Stop Button to begin
disinfecting.
Automatic mode:
Disinfecting will start in 30
seconds.
Solid/Flashing
Orange
Ensure doors are properly closed.
Solid/Flashing
Red
System error. Please contact AVer’s technical support
team:
3. Use
the
Time Slide Switch
to select the disinfecting duration: 5, 10, 15 or 20
minutes.
[Note]
The sanitizing duration can be reselected even when the UV lamps are