AVer EMC1000 Скачать руководство пользователя страница 30

 

 

28 

 

For a period of time beginning on the date of purchase of the applicable product and extending as set 
forth  in  the  “

Warranty  Period  of  AVer  Product  Purchased

”  section  of  the  warranty  card,  AVer 

Information  Inc.  (“AVer”)  warrants  that  the  applicable  product  (“Product”)  substantially  conforms  to 
AVer’s documentation for the product and that its manufacture and components are free of defects in 
material and workmanship under normal use. “You” as used in this agreement means you individually 
or  the  business  entity  on  whose  behalf  you  use  or  install  the  product,  as  applicable.  This  limited 
warranty  extends  only  to  you  as  the  original  purchaser.  Except  for  the  foregoing,  the  Product  is 
provided “AS IS.” In no event does AVer warrant that You will be able to operate the Product without 
problems o

r interruptions, or that the Product is suitable you’re your purposes. Your exclusive remedy 

and  the  entire  liability  of  AVer  under  this  paragraph  shall  be,  at  AVer’s  option,  the  repair  or 
replacement of the Product with the same or a comparable product. This warranty does not apply to 
(a) any Product on which the serial number has been defaced, modified, or removed, or (b) cartons, 
cases, batteries, cabinets, tapes, or accessories used with this product. This warranty does not apply 
to  any  Product  that  has  suffered  damage,  deterioration  or  malfunction  due  to  (a)  accident,  abuse, 
misuse,  neglect,  fire,  water,  lightning,  or  other  acts  of  nature,  commercial  or  industrial  use, 
unauthorized  product  modification  or  failure  to  follow  instructions  included  with  the  Product,  (b) 
misapplication of service by someone other than the manufacturer’s representative, (c) any shipment 
damages (such claims must be made with the carrier), or (d) any other causes that do not relate to a 
Product defect. The Warranty Period of any repaired or replaced Product shall be the longer of (a) the 
original Warranty  Period or (b) thirty (30) days from the date of delivery of the repaired or replaced 
product. 

LIMITATIONS OF WARRANTY 

AVer  makes  no  warranties  to  any  third  party.  You  are  responsible  for  all  claims,  damages, 
settlements, expenses, and attorneys’ fees with respect to claims made against you as a result of your 
use  or  misuse  of  the  Product.  This  warranty  applies  only  if  the  Product  is  installed,  operated, 
maintained,  and  used  in  accordance  with  AVer  specifications.  Specifically,  the  warranties  do  not 
extend  to  any  failure  caused  by  (i)  accident,  unusual  physical,  electrical,  or  electromagnetic  stress, 
neglect  or  misuse,  (ii)  fluctuations  in  electrical  power  beyond  Aver  specifications,  (iii)  use  of  the 
Product  with  any  accessories  or  options  not  furnished  by  AVer  or  its  authorized  agents,  or  (iv) 
installation, alteration, or repair of the Product by anyone other than AVer or its authorized agents. 

DISCLAIMER OF WARRANTY 

EXCEPT  AS  EXPRESSLY  PROVIDED  OTHERWISE  HEREIN  AND  TO  THE  MAXIMUM  EXTENT 
PERMITTED  BY  APPLICABLE  LAW,  AVER  DISCLAIMS  ALL  OTHER  WARRANTIES  WITH 
RESPECT TO THE PRODUCT, WHETHER EXPRESS,  IMPLIED, STATUTORY OR OTHERWISE, 
INCLUDING WITHOUT LIMITATION, SATISFACTORY QUALITY, COURSE OF DEALING, TRADE 
USAGE OR PRACTICE OR THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS  FOR 
A PARTICULAR PURPOSE OR NONINFRINGEMENT OF THIRD PARTY RIGHTS. 

 

 

 

 

 

 

LIMITED WARRANTY 

Содержание EMC1000

Страница 1: ...www aver com EMC1000 User s Manual ...

Страница 2: ... Web Accessing 11 SIP Configuration 12 SIP Interface 13 Built in Registrar Proxy 13 External Registrar 13 Outbound Proxy 14 Use Built in SIP Registrar 14 Add SIP Users 15 Show and Edit SIP Users 15 Access Numbers 16 Configure Access Numbers 16 Date and Time 17 Maintenance 18 upgrade 19 Conference Meeting Summary 19 Conference Meeting Settings 20 Content Sharing 21 USAGE OF EMC1000 21 Dialing to a ...

Страница 3: ...2 FEDERAL COMMUNICATIONS COMMISSION STATEMENT CLASS A 30 COPYRIGHT 31 Trademarks 31 Disclaimer 31 ...

Страница 4: ...ystems Support AVer EZMeetup application for PC and iOS Support compatible room system videophones VoIP phone client software and IP PBX Maximum capacity VGA 640x480 up to 10 viewable parties or CIF 352x240 up to 2 rooms total 12 viewable parties You can use EMC1000 built in SIP registrar or register EMC1000 as client to IP PBX or both Near end and far end NAT and firewall traversal Support H 264 ...

Страница 5: ......

Страница 6: ...wer alive Before service the system shutdown the system and pull the power plug off 3 RESET Button Reboot the system BACK PANEL Name Function 1 POWER Port Connect the power supply cord to a suitable power outlet 2 LAN2 Port 3 Ethernet Port PCI E Run the included gray CAT6 cable from 2 to 3 4 LAN1 port Run the included orange cross cable to a PC to start your initial configuration 5 serial port In ...

Страница 7: ...wered off EMC1000 factory IP address is 192 168 0 1 1 If you decide to put EMC1000 on the rack use the screws to secure it to rack 2 Connect the power cable 3 Connect the beige gray CAT6 cable between LAN2 and PCI E 4 Connect the orange cross cable between LAN1 and PC INITIAL SETUP ...

Страница 8: ...ess and Subnet mask indicating below Make sure the orange cross cable is connected properly from LAN1 on EMC1000 to the PC you just did the network setting change Open internet browser on that PC type in 192 168 0 1 in URL hit enter EMC1000 login screen appears in browser CHANGE THE language via top left corner language drop down list if needed EMC1000 default login is username admin and password ...

Страница 9: ... EMC1000 is located behind a firewall and is configured with private IP address the signaling sent from the EMC1000 messages will contain private IP addresses Unless the firewall provides VoIP NAT Traversal services sessions will not connect as the singling messages will contain non routable addresses This issue is called Near End NAT traversal as the problem to be solved is near meaning the close...

Страница 10: ...s the actual public IP address of these packets and sends the transmitted RTP packets to this address Far end NAT traversal is applied automatically and no setting in needed in EMC1000 In order for this topology to work the SIP clients located behind the local firewall must support Near end NAT traversal Near end NAT traversal for SIP clients requires the SIP clients sending their routable in most...

Страница 11: ...000 meeting directly you will assign a public IP or public URL Also you need to open firewall pinholes for EMC1000 You can also put EMC1000 in DMZ Demilitarized Zone of firewall with LAN and public IP address If you have an EMC1000 compatible IP PBX and like to have EMC1000 and HVC EVC register to PBX as SIP clients You may put EMC and HVC EVC all inside LAN To allow guests or remote employees par...

Страница 12: ...ot 4 If you set the network to DHCP IP address may change usually not recommended and only Hostname is editable Hostname and DNS are very important for firmware upgrade SIP call with domain name and NAT firewall traversal Make sure you remove the cross cable and connect EMC1000 to production network when EMC1000 reboots Change your PC network setting back to the original setting e g DHCP Enter EMC...

Страница 13: ... you can click on specific user account to edit naming or password Or click on to create additional users Admin role has full access to all EMC1000 settings User can only create view and control the conference meeting You can delete an existing user by clicking ...

Страница 14: ...12 SIP CONFIGURATION SIP parameters are in SIP CONFIGURATION Click to start editing ...

Страница 15: ...n the system If the box is checked non managed users are not allowed to register with the system Authentication Realm String Authentication realm of EMC1000 built in Registrar for REGSITER digest challenge any string can be used SIP Users Add Users Used to add new users to the system This function is applicable only when Enable Registrar Proxy and REGISTER Authenticate Required check boxes have be...

Страница 16: ...e Outbound proxy server port 1 Click to discard the changes and revert to previous settings Click to save the changes 2 If any SIP parameter has been modified then all the active calls will be dropped and the application will restart In this case the user s confirmation is required 3 Click OK the application restarts and the new configuration is applied USE BUILT IN SIP REGISTRAR If you are settin...

Страница 17: ...ing from it SIP URI Type a full SIP URI or a partial string of it Status Choose Any Registered and NON Registered options to see all the users registered or non registered users accordingly using the drop down menu 5 Pressing on Refresh resets the filter and the original list re appears on the screen Managed Users 6 Managed Users are users that are provisioned in the system Non Managed Users are u...

Страница 18: ... a participant does not match any of the provisioned access numbers or conference numbers the call is declined CONFIGURE ACCESS NUMBERS Select System Settings Access Numbers Click Create a new number Enter the access number participant needs to dial and video quality from Voice Only Video Chat CIF 352x288 VGA 640x480 You can save it without further steps by clicking If you like to register the acc...

Страница 19: ...17 DATE AND TIME 1 You can set date time and time zone manually or use NTP server to auto set it 2 To set date and time System Settings Date Time 3 After you finish click to save the changes ...

Страница 20: ...n the server will completely power off Start Diagnostic Trace System events are collected during a specified interval a trace file for advanced diagnostic is created Enter the intervals for information collection between 0 to 300 seconds Any number other than 0 will create a detailed log If 0 is entered the system will create a system configuration and minimum log information A diagnostic file zip...

Страница 21: ...g Please wait appears followed by a Reboot confirmation button If you have problem please contact our technical support CONFERENCE MEETING SUMMARY You can select the CONFERENCES from top center menu it brings up a summary of active conferences meetings For example meeting room 400 is active busy this video multimedia call starts at 11 50a 8 8 2012 with 3 participants You can click to view more det...

Страница 22: ...d Voice Only Bandwidth Allocation Low Medium High EMC1000 uses Low as a default value for every new conference room s Bandwidth Allocation parameter If there are no bandwidth restrictions in your environment you may use Medium or High for enhanced video quality Video Layout Type Equal Layout Dominant Based The type of the video conference layout EMC1000 uses Dominant based as the default value for...

Страница 23: ...g a conference meeting hosted by EMC1000 After you dial in to the conference room have your content ready from computer through VGA in port or ScreenShare software press present button on HVC EVC remote controller All HVC or EVC systems and EZMeetup app will receive the content EZMeetup and other EMC1000 compatible terminals can receive content sending from HVC and EVC DIALING TO A CONFERENCE If t...

Страница 24: ... Connected to conference Conference Number Dial 100 Prompt Please enter the conference PIN number followed by the key Dial 1 Connected to conference Access Number Dial 500 Prompt Please enter your conference number followed by the key Dial 100 Connected to conference Conference Number Dial 100 Connected to conference Participant is not registered Dialing Option PIN Code Operations and Prompts Acce...

Страница 25: ... Total bandwidth usage of incoming and outgoing sessions updated every 5 seconds displayed at the top of the toolbar Operational Buttons The following operational buttons appear at the left side of the Leader Dashboard window Invite Participants Enables the leader to invite participants to join the conference Mute Unmute All Participants Show Statistics Displays the conference s detailed statistic...

Страница 26: ...abled Video only conference Participant voice muted Visible participant Voice only participant Participant video disabled Remove participant When you click on more detailed information appear You can change the meeting layout in leader dashboard as well One of two layouts can be chosen ...

Страница 27: ...croll bar to view all the participan s information Set the Auto Refresh check box to update the displayed information automatically The information is updated every 5 seconds The rows in the statistics table above can be set or reset by clicking on the Rows Settings button To invite paticipants click on that button Enter the name or number of who you want to invite appears in the registration to S...

Страница 28: ...26 ...

Страница 29: ... 1H Rated Output Voltages 3 3V 8A 5V 8A 12V 16A 12V 0 5A 5Vsb 2A Operating Environment Operating Temperature 10º to 35º C 50º to 95º F Non operating Temperature 40º to 70º C 40º to 158º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Control Information Web based GUI EMC1000 web based GUI supports Internet Explorer 8 or newer Google Chrom...

Страница 30: ...w instructions included with the Product b misapplication of service by someone other than the manufacturer s representative c any shipment damages such claims must be made with the carrier or d any other causes that do not relate to a Product defect The Warranty Period of any repaired or replaced Product shall be the longer of a the original Warranty Period or b thirty 30 days from the date of de...

Страница 31: ...TY OR THE USE OR PERFORMANCE OF ANY PRODUCT WHETHER BASED ON CONTRACT OR TORT INCLUDING NEGLIGENCE OR ANY OTHER LEGAL THEORY EVEN IF AVER HAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AVER S TOTAL AGGREGATE LIABILITY FOR DAMAGES OF ANY NATURE REGARDLESS OF FORM OF ACTION SHALL IN NO EVENT EXCEED THE AMOUNT PAID BY YOU TO AVER FOR THE SPECIFIC PRODUCT UPON WHICH LIABILITY IS BASED GOVERNING LAW AN...

Страница 32: ...erference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver...

Страница 33: ...ither expressed or implied is made with respect to the contents of this documentation its quality performance merchantability or fitness for a particular purpose Information presented in this documentation has been carefully checked for reliability however no responsibility is assumed for inaccuracies The information contained in this documentation is subject to change without notice In no event w...

Отзывы: