Note: Mark 1 expresses in binary as this mode “ 0

0

0

0

bit3

bit2

bit1

bit0 ”

bit0 to bit3 

means  the  marks  of  signals  at  input  channel  1  to  4  respectively

if  the  bit  value  is  1

then  the 

corresponding input channel has signal, or if the bit value is 0, the corresponding input channel has 
not  signal.  So  to  the  Mark  2

its  value  expresses  the  signals  of  the  input  channel  5  to  8.  So  to  the 

Mark  3

its  value  expresses  the  signals  of  the  input  channel  9  to  12.  So  to  the  Mark  4

its  value 

expresses the signals of the input channel 13 to 16.   

For example 1

  Get the marks of signals at input channels   

Commands: 0xeb, 0x90, 0x03, 0x01, 0x00   
Response: 0xeb, 0x90, 0x03, 0x04, 0x08, 0x04, 0x00, 0x00, Redundancy   
Explanation: At this time, the Mark 1 is 08H and the Mark 2 is 04, 0x08 expressed in binary is“0

0

0

0

1

0

0

0 ”

  so the input channel 4 has signal and the input channel 1 to 3 have not 

signals; 0x04 expressed in binary is“0

0

0

0

0

1

0

0”

so the input channel 7 has signal 

and the input channel 5,6 and 8 have not signal, other input channels have no signal.

   

 

Function 2   

Get the Preset Input Channel   

Format   

0xeb, 0x90, 0x03, 0x01, 0x01   

Response   

0xeb, 0x90, 0x03, 0x01, Preset Input Channel

Redundancy   

Note: The range of the Preset Input Channel is as same as the Maximal Input Channel   

For example

  Get the Preset Input Channel   

Commands: 0xeb, 0x90, 0x03, 0x01, 0x01   
Response: 0xeb, 0x90, 0x03, 0x01, 0x04, Redundancy   
Explanation: The Preset Input Channel is input channel 5.

   

 

Function 3   

Get the mark of the load at the output channels   

Format   

0xeb, 0x90, 0x03, 0x01, 0x04   

Response   

0xeb, 0x90, 0x03, 0x05, Mark 1, Mark 2, Mark 3, Mark 4, Mark 
5,Redundancy   

Note: Mark 1 expresses in binary as this mode “ 0

0

0

0

bit3

bit2

bit1

bit0 ”

bit0 to bit3 

means  the  marks  of  Load  at  output  channel  1  to  4  respectively

if  the  bit  value  is  1

then  the 

corresponding output channel has load, or if the bit value is 0, the corresponding output channel has 
not load. So to the Mark 2

its value expresses the signals of the output channel 5 to 8. So to the Mark 

3

its value expresses the signals of the output channel 9 to 12. So to the Mark 4

its value expresses 

the  signals  of  the  output  channel  13  to  16.  So  to  the  Mark  5

its  value  expresses  the  signal  of  the 

output channel 17.   

For example

  Get the mark of the load at the output channel   

Commands: 0xeb, 0x90, 0x03, 0x01, 0x04   
Response: 0xeb, 0x90, 0x03, 0x05, 0x05, 0x01, 0x00, 0x00, 0x00, 0x9b   
Explanation: At this time, the Mark 1 is 0x05 and the Mark 2 is 0x01, 0x05 expressed in binary is“0

0

0

0

0

1

0

1 ”

  so the output channels 1 and 3 have loads and the output channels 2 and 

4 have not loads; Mark 2 0x01 expressed in binary is“0

0

0

0

0

0

0

1”

so the output 

channel 5 has load. Other output channels have no loads.

   

 

5.

 

Command 0x04(three functions)   

Function 1   

Get the tied status of an appointed input channel   

Format   

0xeb, 0x90, 0x04, 0x02, 0x01, Input Number 

Содержание SW-DVI-16X16

Страница 1: ...ns at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth in Avenview Standard Terms and Cond...

Страница 2: ...wer On 6 2 1 3 Lock or Unlock the Panel 7 2 1 4 Switch Input Channel to Output Channel 7 2 1 5 Macro Operation 8 2 1 6 Test Signal Board 10 2 1 7 Other Functions 11 Section 3 System Management 12 3 1...

Страница 3: ...www avenview com 3...

Страница 4: ...defect Removal installation and set up service charges 1 2 Safety Instructions Do not dismantle the housing or modify the module Dismantling the housing or modifying the module may result in electric...

Страница 5: ...aging the device LED status to indicate the source and output displayed Supports up to 1600x1200 resolution Embedded circuit in device to generate signals for testing and debugging systems 1 5 Package...

Страница 6: ...e DVI output of the source DVI signal to IN1 IN16 of the SW DVI 16X16 Matrix Switch Connect the DVI cable to output connector of the SW DVI 16 16 2 2 Device Operation 2 1 1 Front Panel 2 1 2 Device Po...

Страница 7: ...I O or ENTER button The format symbol will blink Troll the ENTER button to select the format symbol from A V and A V and press the I O or ENTER button to set the format symbol Format Symbol A Operatio...

Страница 8: ...ished setting the channel 2 1 5 Macro Operation If the panel locked the device will have a bell warning when press the MACRO button or if the panel unlocked the LED will display the MACRO menu as the...

Страница 9: ...orresponding input channel if displays OFF means output channel is off if displays means output channel is ignored LOCK the panel if finished setting the Macro Example Modify Macro 8 If you want to se...

Страница 10: ...the I O menu Set both the output channel and the input channel to be 17 with the I O button and the ENTER button 3 Press the I O button or the ENTER button will tie output channel T1 to input channel...

Страница 11: ...u the cursor is at Input channel number Signal symbol if displays 1 the corresponding input channel has active signal or no signal You can view each input channel signal symbol through trolling ENTER...

Страница 12: ...counted by the sending part when sending data and by the device when send back the data Method Redundancy Address Command Data length Data 1 Data n If Redundancy EBH then Redundancy 14H If Redundancy...

Страница 13: ...it of the inputted masking 0 default g Press enter and then showing as follows Change the passport of telnet N h Press enter then showing as follows Change set 0 server setting 1 serial interface sett...

Страница 14: ...ervision function about working state data such as device s inside temperature and power voltage and control device s input and output via web After set up a correct net control parameter IP address t...

Страница 15: ...pment receives correctly but is controlled through keyboard Then doesn t execute the command and response as follows 0xeb Address Command 0x01 0xf3 Redundancy d The equipment receives the address corr...

Страница 16: ...inted input channels Format 0xeb 0x90 0x02 N Output Number 1 Input Number 1 Output Number N Input Number N Response 0xeb 0x90 0x02 0x01 0xfa Redundancy Note The range of N is the even from 0x02 t0 0x2...

Страница 17: ...mmands 0xeb 0x90 0x03 0x01 0x01 Response 0xeb 0x90 0x03 0x01 0x04 Redundancy Explanation The Preset Input Channel is input channel 5 Function 3 Get the mark of the load at the output channels Format 0...

Страница 18: ...annel 8 Function 3 Get the tied status of all output channels Format 0xeb 0x90 0x04 0x01 any data except 0xeb Response 0xeb 0x90 0x04 0x08 Input Number of output channel1 Input Number of output channe...

Страница 19: ...tput channels are ignored Function 2 View Macro Format 0xeb 0x90 0x0c 0x02 0x02 Macro Number Response 0xeb 0x90 0x0c N Macro Number Output Number 0 Input Number 0 Output Number M Input Number M Redund...

Страница 20: ...nse 0xeb 0x90 0xfd 0x01 0xfa Redundancy For example Copy the default EDID to the input channel 5 Commands 0xeb 0x90 0xfd 0x02 0x02 Redundancy 10 Command 0xfa nine functions Function 1 Get the signal m...

Страница 21: ...Board is 36 Other boards are not exit Function 4 Get the Voltage value of the control boards Format 0xeb 0x90 0xfa 0x02 0x00 0x03 Response 0xeb 0x90 0xfa 0x05 0x00 Data 1 Voltage value Data 4 Voltage...

Страница 22: ...n 7 Set the length of inputs cable Format 0xeb 0x90 0xfa 0x04 0x00 0x0b the input channel the Value of the length Response 0xeb 0x90 0xfa 0x01 0xfa 0x85 Note The Value of the length is from 0x00 to 0x...

Страница 23: ...9 4F c 99 63 w 119 77 40 28 60 3C P 80 50 d 100 64 x 120 78 41 29 61 3D Q 81 51 e 101 65 y 121 79 42 2A 62 3E R 82 52 f 102 66 z 122 7A 43 2B 63 3F S 83 53 g 103 67 123 7B 44 2C 64 40 T 84 54 h 104 68...

Страница 24: ...C 5 Response by the device Out Multi In 05 DVI Macro command Function 1 Set Macro Format M X5 X3 X2 X3 X2 E Response Sma X5 For example Set Macro 6 Macro 6 tie the input channels 16 15 14 13 12 11 10...

Страница 25: ...e control board The corresponding relation is as follows Voltage NO Normal voltage Voltage step 1 2 5V 6 51mV 2 2 5V 5 86mV 3 5 0V 13 02mV 4 12 0V 31 25Mv The actual temperature Data n 4 corresponding...

Страница 26: ...ple Get device temperature Commands sent by PC 1 5S Response by the device 1Tem51 Explanation The actual temperature is 31 Get the EDID of Outputs to Inputs Function Copy the EDID of the output channe...

Страница 27: ...of Input Ensure that equipments have signal by operating them Change the PC s resolution No Signal Output and IN LED is ON The cable of output is not connected The device is not outputting signal Che...

Страница 28: ...Connector DB9 Male Input Resolution 1600x1200x60Hz Supported Input Signal DVI 1 0 Supported Output Signal Same as Input Standard Pixel Clock Frequency 24MHz 165MHz Control Options RS232 or TCP IP 10M...

Страница 29: ...atory profits or for punitive incidental or consequential damages in connection with the furnishing performance or use of the Avenview hardware software or other products and documentation provided he...

Отзывы: