www.avenview.com
16
For example
:
Get the information of equipment’s type
Commands: 0xeb, 0x90, 0x00, 0x01, 0x49
Response: 0xeb, 0x90, 0x00, 0x03, 0x80, 0x10, 0x10, Redundancy
2.
Command 0x01
Function
Tie the input channel to output channel
Format
0xeb, 0x90, 0x01, N, Input Number of output channel
1…Input Number of output channel N.
Response
0xeb, 0x90, 0x01, 0x01, 0xfa, Redundancy
Note: The range of N is from 0x01 to 0x11.
Note: The range of Input Number is from 0x00 to 0x11. 0 means INPUT 1, 1 means INPUT 2, 0x11
means closing output.
For example 10
:
Tie the input channel 8 to the output channel 1, the input channel 17 to the output
channel 2 and close the output channel 3.
Commands: 0xeb, 0x90, 0x01, 0x03, 0x07, 0x10, 0x11
Response: 0xeb, 0x90, 0x01, 0x01, 0xfa, Redundancy
3.
Command 0x02
Function
Tie the appointed output channels to the appointed input
channels.
Format
0xeb
,
0x90, 0x02, N, Output Number 1,Input Number
1,…,Output Number N, Input Number N
Response
0xeb, 0x90, 0x02, 0x01, 0xfa, Redundancy
Note: The range of N is the even from 0x02 t0 0x22.
Note: The range of Output Number is from 0x00 to 0x10. 0x10 stands for the test output.Note 3: The
range of Input Number is from 0x00 to 0x11. 0x11 is used to close the output. 0x10 is used to tie the
output to the internal test signal.
For example 1
:
Tie the input channel from 1 to 8 to output channel from 1 to 8 respectively.
Commands: 0xeb, 0x90, 0x02, 0x10, 0x00, 0x00, 0x01, 0x01, 0x02, 0x02, 0x03, 0x03, 0x04, 0x04, 0x05,
0x05, 0x06, 0x06, 0x07, 0x07
Response: 0xeb, 0x90, 0x02, 0x01, 0xfa, Redundancy
For example 2
:
Tie the input channel 2 to the output channel 8
Commands: 0xeb, 0x90, 0x02, 0x02, 0x07, 0x01
Response: 0xeb, 0x90, 0x02, 0x01, 0xfa, Redundancy
4.
Command 0x03(three functions)
Function 1
Get the marks of signals at input channels
Format
0xeb, 0x90, 0x03, 0x01, 0x00
Response
0xeb, 0x90, 0x03, 0x04, Mark 1, Mark 2, Mark 3, Mark
4,Redundancy