background image

 

VID-ALARM-8CH-COM 

Reference Manual 

 

 

 

Please

 

read

 

these

 

instructions

 

and

 

keep

 

for

 

later

 

reference.

 

NOTES:

 

1.

 

Do

 

not

 

use

 

in

 

extreme

 

heat

 

or

 

cold

 

temperatures.

 

2.

 

Do

 

not

 

expose

 

to

 

rain

 

or

 

moisture

 

3.

 

Do

 

not

 

expose

 

to

 

flammable,

 

explosive,

 

or

 

corrosive

 

gas.

 

4.

 

Avoid

 

exposure

 

to

 

dust

 

or

 

other

 

particles

 

that

 

may

 

get

 

inside

 

the

 

equipment.

 

5.

 

Use

 

of

 

extension

 

cords

 

may

 

significantly

 

increase

 

risk

 

of

 

fire,

 

electric

 

shock,

 

and

 

damage

 

to

 

the

 

equipment.

 

6.

 

To

 

avoid

 

risk

 

of

 

electric

 

shock

 

and

 

damage

 

to

 

equipment

 

do

 

not

 

open

 

the

 

device.

 

7.

 

Professional

 

installation

 

is

 

required.

 

Содержание VID-ALARM-8CH-COM

Страница 1: ...or moisture 3 Do not expose to flammable explosive or corrosive gas 4 Avoid exposure to dust or other particles that may get inside the equipment 5 Use of extension cords may significantly increase ri...

Страница 2: ...rew d Power Adapter Additional Items Included Back Panel Front Panel Brief Introduction Alarm in 8 port Normal Open Normal Close Input Voltage 0 15V Alarm out 8 port Normal Open Normal Close connector...

Страница 3: ...channel relay outputs NO Alarm linkage function Watchdog function auto reset function in strong reference environment Open circuit and short circuit arm function Provide protocol 16 ID setting connec...

Страница 4: ...dance with the host computer protocol 6 Connection Operate as following figure to connect alarm probe and connect a resistance 2K in series connection at NO contact S signal ground wire 7 Protocol set...

Страница 5: ...ing please refers to the table below The number 1 means the DIP switch setting should be ON and the number 0 means OFF Note the ID number is binary digit ID Switch number 1 2 3 4 0 0 0 0 0 1 0 0 0 1 2...

Страница 6: ...0 0F D2 A0 A7 A8 A15 A 0 15 is corresponding to outputs 1 16 1 ON 0 OFF Note 1 The data4 data5 of this alarm box is 0 NOTES ____________________________________________________________________________...

Страница 7: ...be certain to have full details about your Aventura products available including model and invoice numbers Service Any service required by this unit should be performed by Aventura or authorized servi...

Отзывы: